Checking The Navigation Interface - Raymarine ST1000 Plus Tiller Pilots Owner's Handbook Manual

Hide thumbs Also See for ST1000 Plus Tiller Pilots:
Table of Contents

Advertisement

52
Reversing the operating sense
If necessary, reverse the operating sense can be reversed as follows:
1. Press -1 and +1 together for 5 seconds.
2. The display shows the new operating sense (port or starboard) for

Checking the navigation interface

If you have connected the tiller pilot to a navigator, check the
interface as follows:
1. Set up a track on the navigator to give a Cross Track Error
2. Enter Auto mode by pressing auto .
3. Enter Track mode by pressing -10 and +10 together.
4. An alarm will sound and the display will alternate between the
5. Make sure that it is safe to turn onto the new course, then press
6. If the navigator is connected correctly, the display will begin to
ST1000 Plus & ST2000 Plus Tiller Pilots - Owner's Handbook
5 seconds, and then the autopilot reverts to normal operation.
between 0 nm and 0.3 nm.
bearing to waypoint and the direction the boat will turn to
acquire it.
-10 and +10 again.
cycle through the available navigation data:
D208-2
Locked heading
Distance to waypoint
(if available)
Bearing to waypoint
(if available)
Cross track error
D3267-2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

St2000 plus tiller pilots

Table of Contents