High Voltage Power Supply Removal - Toshiba e-STUDIO500P Service Manual

Table of Contents

Advertisement

High voltage power supply removal

CAUTION: There is a danger from hazardous voltage in the area of the printer where you are
working. Unplug the printer before you begin, or use caution if the printer must receive power in
order to perform the task.
1.
Remove the inner paper deflector. See
2.
Remove the right side cover. See
3.
Disconnect the HVPS cable from the HVPS at connector (A).
4.
Disconnect the transfer roll cable (B) from the HVPS board.
Warning:
"Right cover removal" on page
A
Use care when disconnecting the cable from the transformer on the HVPS. The cable and
connector can be easily damaged.
"Inner paper deflector assembly removal" on page
4-8.
Repair information
4-47.
4-45