4 Assembly

5 Installation

4.5

Mounting the appliance

240
75
75
50
50
85
1
3
Fig. 4.4 Mounting the appliance
• Fix the hanging bracket (1) to the wall using the plugs
and screws (2) provided with the appliance.
• Hang the top of the appliance (3) onto the hanging
bracket using the suspension bracket.
4.6

Removing the front case

Fig. 4.5 Removing the front case
To disassemble the front housing of the appliance, pro-
ceed as follows:
• Release the screw (1) on the bottom of the appliance.
• Push both the clamps (2) on the bottom of the appli-
ance together so that the front cladding releases.
• Pull the housing forwards at the lower edge and re-
move the front cladding upwards.
12
2
23
2
1
5
Installation
d
Danger!
The Vaillant ecoTEC exclusive may only be in-
stalled by a suitably qualified heating engineer
approved at the time by the Health and Safety
Executive who also assumes the responsibility
for installing the appliance properly and fully
commissioning the appliance prior to first use,
along with demonstrating its correct use to the
end user.
5.1

General instructions for heating system

a
Caution!
Flush the heating system thoroughly before
connecting the appliance!
By doing that, residue such as welds, cinder,
hemp, putty, rust, rough dust and similar sub-
stances are removed from the pipes. Otherwise
such substances can be deposited in the appli-
ance and cause damage.
5.2

Gas connection

d
Danger!
The gas installation may only be established by
an authorised engineer approved at the time by
the Health and Safety Executive. The legal di-
rectives and the local regulations for gas sup-
ply companies must be observed.
a
Caution!
Ensure stress-free assembly of the gas pipes
to avoid leakages!
Caution!
a
The gas regulating block may be tested for
leakage only with a maximum pressure of
110 mbar! The operating pressure may not
exceed 60 mbar. If these pressures are
exceeded, the gas fitting may be damaged.
ecoTEC exclusive installation and maintenance instructions / 0020017768_04

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ecotec exclusive 838