3 Mounting
3.4

Required minimum gaps/assembly clearances

Both for the installation/assembly of the appliance and
for carrying out maintenance tasks later, you need the
minimum gaps and assembly clearances given below:
Fig. 3.3 Required minimum gaps/assembly clearances
Leaving gaps to the sides is not necessary.
Furthermore, it is not necessary to keep a gap between
the appliance and components made of combustible
constituents, since at the rated heating power of the ap-
pliance, the temperature here is never higher than the
permitted temperature of 85 °C.
3.5

Mounting the appliance

• Hang the appliance up into the appliance holder (1)
from above with the bracket (3).
• Mount the cable connections to the appliance, making
sure they are disconnected from the power supply.
240
75
75
50
50
85
1
3
Fig. 3.4 Mounting the appliance
10
350
250
2
23
3.6

Removing/Attaching the appliance casing

Removing the casing
To dismount the front casing of the appliance, proceed
as follows:
• Unscrew the screw (1) on the bottom of the appliance.
• Press in both holding clips (2) on the bottom of the ap-
pliance so that the casing comes loose.
• Pull the casing (3) forwards by its bottom edge and lift
the casing up and off (4).
2
1
Fig. 3.5 Removing/Attaching the appliance casing
Attaching the casing
To mount the casing, proceed as follows:
• Place the casing on the upper appliance holders.
• Push the casing onto the appliance so that the holding
clips (2) on the casing click into place.
• Fix the casing by screwing in the screw (1) on the bot-
tom of the appliance.