Dimensioned Drawing And Dimensions For Connection - Vaillant ecoTEC exclusive 832 Installation And Maintenance Instructions Manual

Gas wall boilers with condensing appliance technology
Table of Contents

Advertisement

4 Assembly
4.2
Dimensioned drawing and dimensions
for connection
Fig. 4.2 Dimensions for connection (mm)
Key to Fig. 4.2
1
Flue connection
2 Mounting bracket
3 Heating return
4 Cold water connection
5 Gas connection
6 Hot water connection
7 Heating flow
10
480
2
6
7
Ø 20
Ø 20
70
100 100
190
4
3
7
25
180
Ø 20
5
ecoTEC exclusive installation and maintenance instructions / 0020017768_04
450