Inductance Measurement - UNI-T UT602 Operating Manual

Digital inductance capacitance meter
Table of Contents

Advertisement

Model UT602/603: OPERATING MANUAL
D. Inductance Measurement (see figure 6)
To test the inductance, please follow the following procedure:
1.
Set the rotary switch to Lx measurement mode.
2.
If the tested inductance value is unknown, use the
maximum measurement position and decrease the range
step by step until a satisfactory reading is obtained.
3.
Insert the test clips into the corresponding Lx input
terminals.
4.
Use the test clips to clip the inductance to carry out the
testing.
5.
The measured value shows on the display.
Remarks:
l
When carrying out measurement at 2mH, short circuit
the test clip first, then carrying out the measurement.
The actual correct reading is the measured reading
minus the short circuit reading.
l
When testing a small value inductance, it is better to use
the small value jack.
l
The Meter cannot check the quality of the inductance.
l
When inductance measurement has been completed,
disconnect the connection between the testing clips and
the circuit under test and remove the testing clips away
from the input terminals of the Meter.
(figure 6)
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ut603

Table of Contents