UNI-T UT50D Operating Manual page 14

Table of Contents

Advertisement

Model UT50D: OPERATING MANUAL
1. Insert the red test lead into thei V
and the black test lead into the COM input terminal.
2. Set the rotary switch to an appropriate measurement
position in V
3. Connect the test leads across with the object being
measured.
The measured value shows on the display.
l If the value of voltage to be measured is unknown,
use the maximum measurement position (1000V)
and reduce the range step by step until a satisfactory
reading is obtained.
l The LCD displays "1" indicating the existing selected
range is overloaded, it is required to select a higher
range in order to obtain a correct reading.
l In each range, the Meter has an input impedance of
approx. 10M . This loading effect can cause
measurement errors in high impedance circuits. If the
circuit impedance is less than or equal to 10k
error is negligible (0.1% or less).
l When DC voltage measurement has been completed,
disconnect the connection between the testing leads
and the circuit under test.
range.
14
nput terminal
, the