Dc Current; Ac Current - UNI-T UT50D Operating Manual

Table of Contents

Advertisement

Model UT50D: OPERATING MANUAL
C. DC Current
Range Resolution
2mA
0.001mA
200mA
20A
Remarks:
l At 20A Range: For continuous measurement 10
seconds and interval not less than 15 minutes.
l Measurement voltage drop: Full range at 200mV.
D. AC Current
Range Resolution
20mA
200mA
20A
Remarks:
l At 20A Range: For continuous measurement 10
seconds and interval not less than 15 minutes.
l Measurement voltage drop: Full range at 200mV.
l Frequency reaponse: 40Hz~400Hz
l Display effective value of sine wave (mean value
response).
Accuracy
(0.8%+1)
(1.5%+1)
0.1mA
10mA
(2%+5)
Accuracy
(1%+3)
0.01mA
0.1mA
(1.8%+3)
10mA
(3%+5)
30
Overload Protection
0.5A. 250V fast type
fuse, 5x20mm
Un-Fused
Overload Protection
0.5A. 250V fast type
fuse, 5x20mm
Un-Fused

Hide quick links: