Esc Ixt2 Select Print Start Trigger - Brother RJ-4030 Software Manual

Software developer's manual p-touch template 2.0 command reference
Hide thumbs Also See for RJ-4030:
Table of Contents

Advertisement

ESC iXT2 Select print start trigger

ASCII:
ESC
Decimal:
27
Hexadecimal: 1B
Parameters
nh1=01h (Fixed)
nh2=00h (Fixed)
00h≤nh3≤02h
Description
Selects the type of print start trigger.
nh3=00h: When the specified text string is received (default)
nh3=01h: When all objects are filled
(Prints with the delimiter at the end of the data.)
nh3=02h: When the specified number of characters is received
(not including delimiters)
This command is a static command.
Remarks
Invalid if nh3 is a value other than 00h through 02h
Example
When the print start trigger is "when all objects are filled":
ESC i X T 2 01h 00h 01h
(1Bh 69h 58h 54h 32h 01h 00h 01h)
i
X
T
2
n1
105 88
84 50 nd1 nd2 nd3
69
58
54 32 nh1 nh2 nh3
n2
n3