Esc Ixd2 Specify Delimiter - Brother RJ-4030 Software Manual

Software developer's manual p-touch template 2.0 command reference
Hide thumbs Also See for RJ-4030:
Table of Contents

Advertisement

ESC iXD2 Specify delimiter

ASCII:
ESC i
Decimal:
27
Hexadecimal: 1B
Parameters
01h≤nh1≤14h
nh2: 00h (Fixed)
00h≤datah≤FFh
Description
The delimiter is used to indicate when to move to the next object in data that is being sent.
Specifies the text string for the delimiter.
nh1+(nh2*256): Length of the text string (between 1 and 20)
data:
The default text string for the delimiter is "09h" (Tab code).
This command is a static command.
Remarks
Invalid if more than 20 characters have been specified
Example
To change the delimiter to "," (2Ch):
Since the text string contains one character, nh1=01h and nh2=00h. In addition, with the text string (datah)
"," (2Ch), the command will be as follows.
ESC i X D 2 01h 00h 2Ch
(1Bh 69h 58h 44h 32h 01h 00h 2Ch)
X
D
2
105 88
68
50 nd1 nd2 datad
69
58
44
32 nh1 nh2 datah
Text string (The maximum number of characters that can be set is 20 characters
(bytes).)
n1
n2
data
- 61 -