3.1 Overview
The FSD-804PS provides a user-friendly, command line under console interface. Using this interface, you can perform
various switch configuration and management activities, including:
Command
Show port [n] / all
Show static(n)
Show VLAN
Show trunk
Show IP
Show system
Show PoE status[n]
Show PoE(n)
Show management VLAN
Show VLAN mode
Show PVID
Set port [n]
Set Trunk
Set VLAN(n)
Set PoE[n]
Set VLAN mode
Set PVID
Set IP xxx.xxx.xxx.xxx, mmm. mmm,
mmm, mmm, ggg.ggg.ggg.ggg
Set Pass
Factory Default
Reboot
Logout
Please refer to the following Chapter 4 and 5 for the details.
Description
Show per port or all port current status
Show per port detail Ethernet traffic pass through
Show current VLAN group status
Show current trunk group test
Show current IP subnet address.
Show firmware version, Mac address and IP address
Show per PoE port status( On or Off)
Show per PoE port disable/enable and priority
Show current management VLAN
Show current VLAN mode of FSD-804PS
Show per port PVID of FSD-804PS
Set per port auto-negotiation speed duplex mode and QoS function
Enable or disable trunk group( port 7,8) of FSD-804PS
Configure VLAN group 1-8
Configure per PoE port
Disable or enable Port-based VLAN function
Assign PVID on each port
Assign IP address, subnet mask, gateway of FSD-804PS
Change the default password of FSD-804PS, the maximum length is 4 characters
Reset the FSD-804PS to factory default mode
Reboot the FSD-804PS
Logout console interface of FSD-804PS

3. SWITCH MANAGEMENT