Planet FSD-804PS User Manual

8-port 10/100mbps with 4-port poe web smart ethernet switch
Hide thumbs Also See for FSD-804PS:

Advertisement

Quick Links

8-Port 10/100Mbps with 4-Port PoE
Web Smart Ethernet Switch
FSD-804PS
User's Manual
- 1 -

Advertisement

Table of Contents
loading

Summary of Contents for Planet FSD-804PS

  • Page 1 8-Port 10/100Mbps with 4-Port PoE Web Smart Ethernet Switch FSD-804PS User’s Manual - 1 -...
  • Page 2: Fcc Warning

    Trademarks Copyright © PLANET Technology Corp. 2006. Contents subject to revision without prior notice. PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners. Disclaimer PLANET Technology does not warrant that the hardware will work properly in all environments and applications, and makes no warranty and representation, either implied or expressed, with respect to the quality, performance, merchantability, or fitness for a particular purpose.
  • Page 3: Table Of Contents

    3.2.2 Web Management........................... 10 3.3 A IP A ....................10 SSIGNING AN DDRESS TO THE WITCH 3.4 L FSD-804PS......................11 OGGING ON TO THE 4. CONSOLE INTERFACE..........................12 4.1 CONNECT TO PC ..........................12 4.2 L ..............................13 OGIN IN 4.3 M ..........................
  • Page 4: Introduction

    With 4 PoE interfaces, the FSD-804PS is ideal for small business and workgroups requiring to deploy the PoE for the wireless access points, IP-based surveillance camera or IP phones in any places easily, efficiently and cost effective.
  • Page 5: Features

    IEEE 802.3af Power over Ethernet. EMI standards comply with FCC, CE class A 1.4 Specification Model FSD-804PS Network Connector 8-Port RJ-45 for 10/100TX, 4-Port with PoE injector function LED Display One power, 1-4 port PoE in-use, LNK/ACT, 100, 5-8 port LNK/ACT, 100 Switch architecture Store and forward switch architecture.
  • Page 6: Hardware Description

    Lights to indicate the port is running in 100Mbps speed. 2.2 Rear Panel The rear panel of the FSD-804PS indicates an AC inlet power socket, which accepts input power from 100 to 240VAC, 50-60Hz, 1A max. and one console port at rear panel for switch management.
  • Page 7: Hardware Installation

    19” rack. Connect the power cord to the power inlet socket of FSD-804PS and the other end into the local power source outlet. When the Switch receives power, the Power LED should remain solid Green.
  • Page 8 Notice: Cable distance for Switch The cable distance between the FSD-804PS and PC should not exceed 100 meter for UTP/STP cable. Make sure the wiring is correct It can be used Category 3/4/5 cable in 10 Mbps operation. To reliably operate your network at 100Mbps, you must use an Unshielded Twisted-Pair (UTP) Category 5 cable, or better Data Grade cabling.
  • Page 9: Switch Management

    - Assigning an IP address to the FSD-804PS - Logging on to the FSD-804PS 3.1 Overview The FSD-804PS provides a user-friendly, command line under console interface. Using this interface, you can perform various switch configuration and management activities, including: Command...
  • Page 10: Management Methods

    The serial port of the Switch default setting is set to 19200 baud using a character format of 8 data bits, no parity, and 1 stop bit. Therefore, configure the terminal or workstation to use these settings before you log on to the FSD-804PS. You can change this default setting, if desired, after you log on.
  • Page 11: Logging On To The Fsd-804Ps

    3.4 Logging on to the FSD-804PS When you log on to the FSD-804PS console port for the first time, a sign-on string appears and you are prompted for a console login user name and password. The factory default login username is admin without password.
  • Page 12: Console Interface

    4. CONSOLE INTERFACE 4.1 CONNECT TO PC RS-232 serial cable Use the bundled RS-232 serial cable and attach the 9-pin female connector to the male connector on the FSD-804PS. Plug the other side of this cable to your PC. Hyper Terminal In Windows 98/2000/ME/XP, launch “HyperTerminal”, create a new connection, and adjust settings as below:...
  • Page 13: Login In

    "admin" without password. You may change the password by use “set pass” command. Please always enter the correct user name and password. (See Figure 4-2) Figure 4-2 FSD-804PS login screen 4.3 Main Menu screen After login the FSD-804PS, the main menu screen shows as below. Figure 4-3 FSD-804PS Main Menu screen - 13 -...
  • Page 14: Getting Started

    4.4 Getting Started 4.4.1 General Guidelines The FSD-804PS allows users to configure the device via command line under console interface. Please type “help” or “?” for all available commands in the”FSD-804PS>” prompt. The screen of available commands in Figure 4-4 appears, and the detail description shown in table 4-1.
  • Page 15: Show Command

    Set IP xxx.xxx.xxx.xxx, mmm. mmm, Assign IP address, subnet mask, gateway of FSD-804PS mmm, mmm, ggg.ggg.ggg.ggg characters Set Pass Change the default password of FSD-804PS, the maximum length is 4 Factory Default Reset the FSD-804PS to factory default mode Reboot Reboot the FSD-804PS...
  • Page 16 Show pvid: Please refer to chapter 4.4.2.11 4.4.2.1 Show port[n] / all Display the status on each port of FSD-804PS, these two commands allows you to view the port status of the Switch and the correct usage is shown as below: Show port [n]: n=1-8, to view per port status of FSD-804PS.
  • Page 17 Figure 4-7 All port Status screen 4.4.2.2 Show static [n] Display the traffic counters on each port of FSD-804PS, this command allows you to view per port traffic counters of the Switch and the correct usage is shown as below: Show static [n]: n=1-8, to view per port traffic counters of FSD-804PS.
  • Page 18 4.4.2.3 Show vlan Display the current VLAN group status of FSD-804PS, the VLAN group status screen in Figure 4-9 appears. Figure 4-9 VLAN group status screen 4.4.2.4 Show trunk Display the current trunk group status of FSD-804PS, the trunk group status screen in Figure 4-10 appears.
  • Page 19 4-11 appears. Figure 4-11 IP subnet address information screen 4.4.2.6 Show system Display the system information of FSD-804PS, such as software version, mac address and IP address. The system in- formation screen in Figure 4-12 appears. Figure 4-12 System information screen...
  • Page 20 4.4.2.7 Show poe status [n] Display the poe link status on each port of FSD-804PS, this command allows you to view per poe port link status of the Switch and the correct usage is shown as below: Show poe status [n]: n=1-4, to view per poe port link status of FSD-804PS. The per poe port link status screen in...
  • Page 21 Display the management vlan of FSD-804PS, the management vlan display screen in Figure 4-15 appears. Figure 4-15 Display management VLAN screen 4.4.2.10 Show vlan mode Display the current vlan mode of FSD-804PS, the vlan mode display screen in Figure 4-16 appears. Figure 4-16 Display VLAN mode screen - 21 -...
  • Page 22: Set Command

    4.4.2.11 Show pvid Display the current per port pvid of FSD-804PS, the per port pvid display screen in Figure 4-17 appears. Figure 4-17 Display pvid screen 4.4.3 Set command From the main menu screen (see Figure 4-3), input “set” and press enter. The set command list screen in Figure 4-18 appears.
  • Page 23 4.4.3.1 Set port [n] This command allows configuring per port parameters of FSD-804PS. the correct usage is shown as below: Set port [n]: n=1-8, to configuring per port parameters of FSD-804PS. The configuring per port parameters screen in Figure 4-19 appears and the detail description shown in table 4-2.
  • Page 24 Figure 4-20 Port Configuration screen 4.4.3.3 Set vlan [n] This command allows configuring eight port-based VLAN groups of FSD-804PS. the correct usage is shown as below: Set vlan [n]: n=1-8, to configuring eight port-based VLAN groups of FSD-804PS. The configuring port-based VLAN...
  • Page 25 4.4.3.4 Set poe [n] This command allows configuring per poe port parameters of FSD-804PS. the correct usage is shown as below: Set poe [n]: n=1-4, to configuring per poe port parameters of FSD-804PS. The configuring per poe port parameters screen in Figure 4-22 appears and the detail description shown in table 4-3.
  • Page 26 4.4.3.6 Set vlan mode This command allows disable or enable port-based vlan function of FSD-804PS, the vlan mode setting screen in Figure 4-24 appears Figure 4-24 VLAN mode Configuration screen 4.4.3.7 Set pvid This command allows assign PVID of each port from FSD-804PS, the PVID setting screen in Figure 4-25 appears.
  • Page 27 4.4.3.8 Set ip xxx.xxx.xxx.xxx.mmm.mmm.mmm.mmm.ggg.ggg.ggg.ggg This command allows assign IP address, netmask and gateway of FSD-804PS. the correct usage is shown as below: set ip 192.168.0.1 255.255.255.0 192.168.0.254 and press <Enter> If the IP is successfully configured, the switch will automatically restart as the following screens. After reboot the Switch and power on completed, you can use the new IP address access of FSD-804PS.
  • Page 28 4.4.3.9 Set pass This command allows assign password of FSD-804PS. The password setting screen in Figure 4-28 appears. Figure 4-28 Password configuration screen Notice: For security reason, please change and memorize the new password after this first setup. The maximum length is 4 characters.
  • Page 29: Factory Default

    4.4.4 Factory default This command allows rest FSD-804PS to factory default mode. The factory default screen in Figure 4-29 & 4-30 appears. Figure 4-29 Factory default screen Figure 4-30 Factory default screen - 29 -...
  • Page 30: Reboot

    4.4.5 Reboot This command allows reboot FSD-804PS, the reboot screen in Figure 4-31 & 4-32 appears. Figure 4-31 Switch reboot screen Figure 4-32 Switch reboot screen - 30 -...
  • Page 31: Logout

    4.4.6 Logout This command provides logout the FSD-804PS, the screen in Figure 4-33 appears. Figure 4-33 FSD-804PS Logout screen - 31 -...
  • Page 32: Web Management

    Before login the Web interface of FSD-804PS, please setup the “IP Address” with local serial console port (RS232 port) and use this IP address to configure FSD-804PS through the Web interface. Or modify your PC’s IP domain to the same with FSD-804PS then use the default IP address (192.168.0.100) to remote configure FSD-804PS through the Web interface.
  • Page 33: Port Status

    Figure 5-2 The web main menu screen of FSD-804PS 5-2 Port Status This section provides current status of each port from FSD-804PS, the screen in Figure 5-3 appears and Table 5-1 de- scribes the port status object of switch. Figure 5-3 FSD-804PS Port Status Web Page screen...
  • Page 34: Port Setup

    Duplex Display half or full duplex mode of each port on FSD-804PS. Flow Control Display the flow control Disable or Enable state of each port on FSD-804PS. Table 5-1 Descriptions of the Port Status screen Objects 5-3 Port Setup This section introduces detail settings of per port on FSD-804PS, the screen in...
  • Page 35: Port Status Counters

    For those selected port, this function could provide you with an individual statistical counter, it is a useful page for ad- ministrator to monitor each port’s usage condition. Also, it is helpful to troubleshooting network problems. The screen in Figure 5-5 appears. Figure 5-5 FSD-804PS Port Status Counters Web Page screen - 35 -...
  • Page 36: Vlan Setup

    A Virtual LAN (VLAN) is a logical network grouping that limits the broadcast domain. It allows you to isolate network traffic so only members of the VLAN receive traffic from the same VLAN members. The FSD-804PS supports port-based VLAN function. In the default configuration with VLAN disable, the screen in Figure 5-6 appears.
  • Page 37: Vlan Setting Example

    Figure 5-7 FSD-804PS port-based VLAN Setting Web Page screen Figure 5-8 FSD-804PS port-based VLAN Setting Web Page screen 5.5.1 VLAN setting example: VLAN scenario 1. Port 8 is the file server port for all the workstations 2. Port 1 to port 7 are different devices that do need to see each other Setup steps 1.
  • Page 38: Port Trunk Setup

    After turn on the port trunk feature, port 7 and port 8 should connect to another switch, such as another FSD-804PS, that also supports port trunk feature to double the bandwidth in between. Otherwise, if the con- nected switch do not support port trunk, it will cause network loop and hangs the whole network.
  • Page 39: Misc Configuration

    Allow user to change the password and maximum up to 4 characters, please refer to chapter 5.7.2 Restore System Default Allow user to reset the FSD-804PS to factory default mode, please refer to chapter 5.7.3 Reboot System Allow user to reboot the FSD-804PS, please refer to chapter 5.7.4...
  • Page 40: System Information

    Allow user disable or enable broadcast storm control function, the available range is disable, 10%, 20%, 40%. The screen in Figure 5-13 appears. IP Address Allow user to assign new IP address of FSD-804PS, after setup completed. Please press “Apply” button and switch will reboot automatically to take effect. Subnet Mask Allow user to assign new Subnet Mask of FSD-804PS, after setup completed.
  • Page 41 Figure 5-12 FSD-804PS Management VLAN options Web Page screen Figure 5-13 FSD-804PS Broadcast Storm Control options Web Page screen - 41 -...
  • Page 42: Password / Access Setting

    5.7.2 Password / Access Setting This section provides password change Configuration of FSD-804PS, please input the old password in “Password” space and input the new password in “New Password” space. After setup completed, please press “Submit” button to take effect and the switch will logout automatically. Please login web interface with new password, the screen in Figure 5-14 &...
  • Page 43: Restore System Default

    Figure 5-16 The FSD-804PS login Web Page screen 5.7.3 Restore System Default This section provides reset FSD-804PS to factory default mode, after choose this function and the following screen ap- pears in Figure 5-17. Please press “OK” button to take effect and the switch will reboot automatically and ask you to re-login web interface with default username “admin”...
  • Page 44 Figure 5-18 The FSD-804PS rebooting Web Page screen Figure 5-19 FSD-804PS Re Login Web Page screen - 44 -...
  • Page 45: Reboot System

    Figure 5-20 The FSD-804PS login Web Page screen 5.7.4 Reboot System This section provides reboot FSD-804PS, after choose this function and the following screen appears in Figure 5-21. Please press “OK” button to take effect and the switch will reboot and ask you to re-login web interface with correct username “admin”...
  • Page 46 Figure 5-22 The FSD-804PS rebooting Web Page screen Figure 5-23 FSD-804PS Re Login Web Page screen - 46 -...
  • Page 47: Firmware Upgrade

    Figure 5-24 The FSD-804PS login Web Page screen 5.7.5 Firmware Upgrade This section provides firmware upgrade of FSD-804PS, after choose this function and the following screen appears in Figure 5-25. Please press “Update” button to continue following firmware upgrade process.
  • Page 48 Figure 5-26 The FSD-804PS firmware upgrade Web Page screen Please press “Browser” to locate the latest firmware of FSD-804PS that deposit in your PC and press “Upgrade” to start the firmware upgrade process. The screen in Figure 5-27 appears. Figure 5-27 The FSD-804PS firmware upgrade Web Page screen...
  • Page 49 Figure 5-28 The FSD-804PS firmware upgrade Web Page screen Then the re-login screen appears in Figure 5-29, please press “Re login” button to re-login web interface of FSD-804PS with latest firmware version, the screen in Figure 5-30 appears. Figure 5-29 The FSD-804PS firmware upgrade Web Page screen...
  • Page 50 Figure 5-30 The FSD-804PS login Web Page screen Notice: Please does not power off the FSD-804PS during firmware upgrade process. - 50 -...
  • Page 51: Poe

    5-8 POE This section provides POE status and POE configuration of FSD-804PS, the POE Status screen in Figure 5-31 appears and Table 5-5 describes the POE status object of FSD-804PS. Figure 5-31 FSD-804PS POE Status Web Page screen Object Description Port Indicate port 1 to port 4.
  • Page 52 The POE Configuration screen in Figure 5-32 appears and Table 5-6 describes the POE Configuration object of switch. After setup completed, please press “Apply” button to take effect. Figure 5-32 FSD-804PS POE Configuration Web Page screen Object Description Port Indicate port 1 to port 4.
  • Page 53: Logout

    5-9 Logout This section allows to logout the FSD-804PS, the screen in Figure 5-33 & 5-34 appears. Figure 5-33 FSD-804PS Logout Web Page screen Figure 5-34 The FSD-804PS login Web Page screen - 53 -...
  • Page 54: Switch Operation

    No packet loss will occur. 6.5 Auto-Negotiation The STP ports on the FSD-804PS switch have built-in "Auto-negotiation". This technology automatically sets the best possible bandwidth when a connection is established with another network device (usually at Power On or Reset).
  • Page 55: Troubleshooting

    Check the LNK/ACT LED on the switch Try another port on the Switch Make sure the cable is installed properly Make sure the cable is the right type Turn off the power. After a while, turn on power again. Why I connect my PoE device to FSD-804PS and it cannot power on? Solution: Please check the cable type of the connection from FSD-804(port 1 to port 4) to the other end.
  • Page 56: Appendix A Networking Connection

    APPENDIX A NETWORKING CONNECTION A.1 Switch‘s RJ-45 Pin Assignments Contact MDI-X 1 (TX +) 2 (TX -) 3 (RX +) 6 (RX -) 4, 5, 7, 8 Not used Not used A.2 RJ-45 cable pin assignment There are 8 wires on a standard UTP/STP cable and each wire is color-coded. The following shows the pin allocation and color of straight cable and crossover cable connection: Figure A-1: Straight-Through and Crossover Cable Please make sure your connected cables are with same pin assignment and color as above picture before deploying the...

Table of Contents