Trane FC Installation & Operation Manual page 4

Unitrane fan-coil & force flo air conditioners 200 to 1,200 cfm, “zo” and later design sequence & “so” and later design sequence
Table of Contents

Advertisement

General
UniTrane fan-coil and Force Flo units are
intended for single zone applications.
These units have load capabilities of 200
to 1200 cfm. See Figure I-GI-1 for unit
components. Fan-coil units are available
as two-pipe, with or without electric heat
(one hydronic circuit) or four-pipe (two
hydronic circuits). Force-Flo units feature
two-pipe hydronic, electric heat only, or
steam only. Also, these units feature a
variety of factory mounted piping
packages.
Units with the three-speed fan switch
only, are available with the switch
mounted on the unit, or shipped sepa-
rately, to be mounted in the occupied
space. The unit mounted three-speed
Factory installed
and tested controls
Removable, noncorrosive,
positively-sloped drain pan that's
easy to clean
Easy to remove fan assembly
16-gage steel construction
Figure I-GI-1. UniTrane fan-coil unit components. Vertical cabinet model is shown.
4
switch option, can be ordered with a low
voltage(24 volts AC) transformer and
three fan speed relays. The ship seperate
three-speed switch option, only comes
with a low voltage (24 volt AC) trans-
former and three fan speed relays.
The Tracer ZN010, ZN510, and ZN520
controllers are included inside the units
control box assembly. These controllers
utilize analog signals from a unit-mounted
control device or from a control device
mounted in the occupied space.
The controls interface option, includes a
24 volt AC transformer, and an interface
terminal board. Controls provided by an
external source, can be tied into the
interface terminal board, utilizing
female spade connectors.
Smaller unit footprint
Quiet operation
Easy filter access
without front panel
removal
general
information
Model Number
Each UniTrane fan-coil and Force-Flo
cabinet heater has a multiple character
model number unique to that particular
unit. To determine a unit's specific options,
reference the model number on the unit
nameplate on the fan scroll. The unit
nameplate also identifies the serial
number, sales order number, and
installation and operating specifications.
Following is a complete description of the
fan-coil model number. Each digit in the
model number has a corresponding code
that identifies specific unit options.
1
/
"
4
Factory assembled,
installed and tested piping
package with IAQ drain pan
to collect condensate
Two, three or
four-row coils
Cleanable closed-
cell insulation (non-
fiberglass)
Damper allows up
to 100% fresh air
UNT-SVX07A-EN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

FfUnitrane fcUnitrane ffUnitrane fckbUnitrane fclb

Table of Contents