Trane FC Installation & Operation Manual page 37

Unitrane fan-coil & force flo air conditioners 200 to 1,200 cfm, “zo” and later design sequence & “so” and later design sequence
Table of Contents

Advertisement

Table I-ER-2. Low vertical free discharge
motors, 115 volt
size
FLA
HP (kW)
03
0.7
.03 (0)
04
0.8
.03 (0)
06
1.1
.03 (0)
Note:
Actual rpm will vary with application and configuration.
Table I-ER-3. Decimal to fractional HP (kW)
conversion
FC
Decimal
02
.03
.07
03
.04
.05
.08
04
.05
.06
.10
.13
06
.07
.12
.16
.24
08
.12
.13
.24
10
.05
.07
.06
.12
.10
.16
.13
.24
12
.05
.12
.06
.13
.10
.24
.13
.24
low vertical
.03
03, 04, 06
Note:
Values for fractional HP's (kW's) are approximate values and
not necessarily the actual HP (kW).
UNT-SVX07A-EN
Installation
Table I-ER-4. Free discharge motors on units with two-row, electric, or steam coils
unit
size
FLA
RPM
02
0.6
H
1090
03
0.7
M
770
04
0.9
L
560
06
1.2
H
1090
08
1.4
M
750
L
560
10
0.9
1.2
H
1115
M
760
12
0.9
L
560
1.4
Table I-ER-5. High static motors on units with two-row, electric, or steam coils
unit
size
FLA
02
1.1
Fraction
03
1.4
1/30
04
1.6
1/15
06
2.6
1/25
08
3.4
1/20
10
1.6
1/12
2.6
1/20
12
1.6
1/16
3.4
1/10
1/8
1/15
Table I-ER-6. Free discharge motors on units with three and four-row coils
1/8
1/6
unit
1/4
size
FLA
1/8
02
0.6
1/8
03
0.8
1/4
04
1.0
1/20
1/15
06
1.4
1/16
1/8
08
1.7
1/10
1/6
10
1.0
1/8
1/4
1.4
1/20
1/8
12
1.0
1/16
1/8
1.7
1/10
1/4
1/8
1/4
1/30
Table I-ER-7. High static motors on units with three and four-row coils
unit
size
FLA
02
1.1
03
1.3
04
2.1
06
3.4
08
3.4
10
2.1
3.4
12
2.1
3.4
Note: Actual rpm will vary with application and configuration. Size 10 & 12 units have two motors.
115 volt
208-230 volt
hp (kW)
FLA
hp (kW)
FLA
.03 (.02)
0.3
.03 (.02)
0.2
.04 (.02)
0.4
.04 (.02)
0.3
.05 (.04)
0.5
.05 (.04)
0.4
.07 (.05)
0.6
.07 (.05)
0.5
.12 (.09)
0.9
.12 (.09)
0.6
.05 (.04)
0.5
.05 (.04)
0.4
.07 (.05)
0.6
.07 (.05)
0.5
.05 (.04)
0.5
.05 (.04)
0.4
.12 (.09)
0.9
.12 (.09)
0.6
115 volt
208-230 volt
hp (kW)
FLA
hp (kW)
FLA
.07 (.05)
0.6
.07 (.05)
0.5
.08 (.06)
0.7
.08 (.06)
0.6
.10 (.07)
0.8
.10 (.07)
0.7
.16 (.12)
1.2
.16 (.12)
1.0
.24 (.18)
1.4
.24 (.18)
1.1
.10 (.07)
0.8
.10 (.07)
0.7
.16 (.12)
1.2
.16 (.12)
1.0
.10 (.07)
0.5
.10 (.07)
0.7
.24 (.18)
0.9
.24 (.18)
1.1
115 volt
208-230 volt
hp(kW)
FLA hpP (kW)
.03 (.02)
0.3
.03 (.02)
.05 (.04)
0.5
.05 (.04)
.06 (.04)
0.6
.06 (.04)
.12 (.09)
0.9
.12 (.09)
.13 (.10)
1.0
.13 (.10)
.06 (.04)
0.6
.06 (.04)
.12 (.09)
0.9
.12 (.09)
.06 (.04)
0.6
.06 (.04)
.13 (.10)
1.0
.13 (.10)
115 volt
208-230 volt
hp (kW)
FLA
hp (kW)
.07 (.05)
0.6
.07 (.05)
.08 (.06)
0.7
.08 (.06)
.13 (.10)
0.9
.13 (.10)
.24 (.18)
1.4
.24 (.18)
.24 (.18)
1.4
.24 (.18)
.13 (.10)
0.9
.13 (.10)
.24 (.18)
1.4
.24 (.18)
.13 (.10)
0.9
.13 (.10)
.24 (.18)
1.4
.24 (.18)
electrical
requirements
277-480 volt
rpm
hp (kW)
H
M
L
.03 (.02)
980
840
655
.04 (.02)
980
780
580
.05 (.04)
1050
780
580
.07 (.05)
1030
780
580
.12 (.09)
1080
800
600
.05 (.04)
1050
780
580
.07 (.05)
1030
780
580
.05 (.04)
1050
780
580
.12 (.09)
108
800
600
277- 480 volt
rpm
hp (kW)
H
M
.07 (.05)
1480
1110
865
.08 (.06)
1400
1175
860
.10 (.07)
1475
1315
1070
.16 (.12)
1400
1070
855
.24 (.18)
1475
1285
975
.10 (.07)
1475
1315
1070
.16 (.12)
1400
1070
855
.10 (.12)
1475
1315
1240
.24 (.18)
1475
1285
975
277-480 volt
rpm
FLA
hp (kW)
H
M
0.2
.03 (.02)
980
840
0.4
.05 (.04)
1080
800
0.5
.06 (.04)
1080
800
0.6
.12 (.09)
1080
800
0.8
.13 (.10)
1080
800
0.5
.06 (.04)
1080
800
0.6
.12 (.09)
1080
800
0.5
.06 (.04)
1080
800
0.8
.13 (.10)
1080
800
277-480 volt
rpm
FLA
hp (kW)
H
M
0.5
.07 (.05)
1480
1110
0.5
.08 (.06)
1500
1355
0.7
.13 (.10)
1580
1375
1.1
.24 (.18)
1475
1285
1.1
.24 (.18)
1475
1285
0.7
.13 (.10)
1580
1375
1.1
.24 (.18)
1475
1285
0.7 .13 (.10 )
1580
1375
1.1
.24 (.18)
1475
1285
L
L
655
600
600
600
600
600
600
600
600
L
865
1110
1240
975
975
1240
975
1240
975
37