Installation On Concrete Slabs, Only For Type Sh - Viessmann Vitosol-F Installation Instructions Manual

Flat-plate collector for installation on supports and wall mounting type sv and sh
Table of Contents

Advertisement

Installation on supports

Installation on concrete slabs, only for type SH

Installation information:
■ Observe the max. load and distance
from the edge of the roof for the on-site
substructure in accordance with DIN
1055.
■ Remove any gravel or similar from the
installation area, cover the surface
with protective building mats and posi-
tion concrete slabs on top of these
mats (see table below).
■ Secure the connection brace onto the
retaining brackets between the sec-
ond and third, the fourth and fifth
supports, etc. (see diagram below).
■ For every 1 to 6 collectors, secure two
cross braces diagonally side by side to
the adjustable supports (see diagram
on page 14).
Calculation in accordance with DIN 1055-4 8/1986 and DIN 1055-5 6/1975
Installation
m
height above
ground
Loads at 25°
kg
Loads at 45°
kg
12
(cont.)
■ The side with the type plate must be
on the outside of the first and last col-
lector (see diagram on page 15).
Secure the pipework on only one col-
lector opposite the side with the type
plate.
!
Securing against slippage Securing against lifting
<8
8–20
20–100
323
561
492
845
Please note
Connection pipes should not
show any signs of damage.
Lubricate O-ring seals only
with the special valve grease
provided.
<8
8–20
800
155
315
1198
132
254
20–100
476
375

Advertisement