Making detailed settings to the central control
unit(s), add-on control unit(s) or room sub
control unit(s)
NOTE:
Make the settings to the central control unit(s), add-on control
unit(s) or room sub control unit(s) respectively. You cannot select
multiple control units at the same time.
The following setting item buttons are displayed in the
"Advanced settings" window.
*
Click either the button
corresponding setting window, and then make the
settings in the displayed window(s). See the detailed
instructions for F or G below.
Close to close the current window and return to
Click
*
the previous window.
F
Settings on [Contact input] window (for central
control unit(s) only)
Set the input method to each of the CONTACT INPUT
terminals.
1
Select the input terminal from S1 to S4 from the pull-
down menu.
2
[Contact type]:
Select either Normally open (NO) or Normally closed
(NC).
3
[Trigger condition]:
Select [None], [Broadcast chime] or [Stop chime] as
the trigger condition. When an input is detected, the
selected action is triggered.
[None]:
None will be triggered if an input is detected.
[Broadcast chime]:
Chime paging to the designated zone is triggered if an
input is detected.
[Stop chime]:
The currently-transmitted chime is stopped if an input is
detected.
Only when [Broadcast chime] is selected, the following
*
items are valid.
26
F
(central control unit(s) only)
G
F or G to open the
[Sound source]:
Select either [Internal sound source] or [External
sound source] as the source of chime. When [Internal
sound source] is selected, select a sound fi le or
sequence from the registered ones in the list.
(You need to register sound fi les (→P. 36) and/or
sound sequences in advance.)
When [External sound source] is selected, select
either "External sound source 1" or "External sound
source 2".
[Chime priority]:
Select the priority of chime paging from among
"Normal", "Priority" and "Urgent".
[Zone name]:
Select the target zone of chime paging from the
registered ones in the list.
4
Repeat step
1 to 3 to make the settings to other
terminals.
5
Click
to close the current window and return to
Close
the previous window.
G
Settings on [Contact output] window
Set the trigger condition to each of the CONTACT OUTPUT
terminals.
1
Select an output terminal from the pull-down menu.
Select from L1 to L8 for the central control unit, and
*
select from L1 to L4 for the add-on control unit and room
sub control unit.
2
[Contact type]:
Select either Normally open (NO) or Normally closed
(NC).
3
[Trigger condition]:
Select the action as the trigger condition from among
the following. When the selected action is detected,
output is triggered.
[None]:
No output will be triggered.
[Calling notice]:
Set ON or OFF for "Normal", "Priority" or "Urgent".
[Door release]:
Select one of the registered sub stations in the list
to which an electric door strike is connected. (Click
Reference , and then select the target station.)
[External sound source] (central control unit(s)
only):
Select either "External sound source 1" or "External
sound source 2" connected to the central control unit.
[PA output]:
Select from among "PA output 1" to "PA output 4"
connected to the control unit.
4
Repeat step
1 to 3 to make the settings to other
terminals.
5
Click
to close the current window and return to
Close
the previous window.