Specifications

Electrical
Separate circuit and equipment ground required.
Evaporator unit
Standard electrical – 115/60/1
Maximum fuse – 15 amps
Amperage – 6 amps
Condenser unit
Standard electrical – 220V, 60Hz, 1 phase
Maximum fuse – 40 amps
Amperage – 21.4 amps
Evaporator plumbing
3/8" OD push-in water inlet
3/4" MPT
Notes: 3/4" vented drain line must slope a minimum of 1/4" per foot (6mm per 30.4cm run).
Drain to be hard piped and insulated.
Water shut-off recommended within 10 feet (3m).
Follett recommends installation of Follett water filter system (part# 00130286) in icemaker
inlet water line.
Ambient
Evaporator unit
Air temperature
Water temperature
Water pressure
Condenser unit
Air temperature
Refrigeration
3/8" liquid line
5/8" suction line
Note:
Rack system installations require a reserve capacity of 10,000 BTU/hr at
0˚F (-18˚C) evaporator temperature.
Evaporator pressure regulator (not supplied) is required.
Weight
Evaporator unit
190 lbs (88kg)
Condenser unit
385 lbs (175kg)
100˚F/38˚C max.
90˚F/32˚C max.
70 psi max. (483 kPa)
120˚F/49˚C max.
50˚F/10˚C min.
45˚F/7˚C min.
10 psi min. (69 kPa)
– 20˚F/-29˚C min.
Ice production
Icemaker capacity/24 hrs.
Ambient Air Temperature F/C
60
F
C
16
50
1231
559
10
1182
60
537
16
70
1146
21
520
1110
80
504
27
90
1074
32
488
5
70
80
90
100
21
27
32
38
1206
1163
1128
1098
lbs
548
528
512
499
kg
1157
1127
1088
1055
lbs
525
512
494
479
kg
1121
1091
1048
1012
lbs
509
495
476
460
kg
1085
1055
1008
969
lbs
493
479
458
440
kg
1049
1019
968
926
lbs
476
463
440
421
kg