Follett HCC1400W Operation And Service Manual page 6

Follett corp. hcc1400a, hcc1400w icemakers operation manual
Table of Contents

Advertisement

Dimensions and clearances
Entire front of icemaker must be clear of obstructions/connections to allow removal.
1" (26mm) clearance above icemaker for service.
1" (26mm) minimum clearance on sides.
The intake and exhaust air grilles must provide at least 170 sq in (968 sq cm) of open area.
Air-cooled model HCC1400A icemakers – 18" (458mm) minimum clearance between discharge and air
intake-grilles.
Front View
Air intake
Side View
21.28" (541mm)
23.50"
(597mm)
CORPORATION
Easton Pennsylvania
MODEL
SERIAL NO
PART NO
SINGLE
FULL LOAD AMPS
VOLTS
HZ
PHASE
208264
MOTOR COMPRESSOR THERMALLY PROTECTED
Stock Module Identification Plate
Module No.
REFRIGERANT
CHARGE
OZ
Product
DESIGN PRESSURE HIGH SIDE
LOW SIDE
PSIG
Service No.
MIN. BRANCH CIRCUIT AMPACITY
AMPS
U
L
U
L
NSF
MADE IN
R
R
THE USA
MAX. BRANCH CIRCUIT FUSE SIZE
AMPS
C
21.05" (535mm)
23.8" (580mm)
6
Ice transport hose connection
NEMA 6-20
right angle
Air exhaust
both sides
G
1/4" FPT
condenser inlet
1/4" FPT
condenser drain
15.56"
(395mm)
6.97"
(177mm)
2.53"
(64mm)
2.72"
(69mm)
3/8" OD push-in water inlet
3/4" MPT drain
Back View
Air exhaust
29.63" (753mm)
2.43" (62mm)