1St/2Nd Stage Cooling; Short Cycle; Residual Cool; Balance Points - Robertshaw 9801i2 User Manual

Deluxe programmable thermostats
Hide thumbs Also See for 9801i2:
Table of Contents

Advertisement

110-1175 English
7/17/06
1:59 PM
SYSTEM SETTINGS
Equipment Setup Menu
1st Stg Cool
2nd Stg Cool

Short Cycle

-----------
Back
WARNING:
Adjusting the Short Cycle protection may damage the cooling equipment. Check with the equipment
manufacturer's recommended settings.
System Settings Menu
Equipment Setup

Residual Cool

Balance Points

Service Intervals
Back
Page 22
page 2 of 5
1st Stage Cool equipment – Select Yes or No.
2nd Stage Cool equipment can be selected for 9825i2 models only – Select Yes or No.
Yes
No
Short Cycle – The minimum time between heating or cooling cycles intended to protect
5Min
your equipment. (See the WARNING below.) Turn it Off or set it from 1 to 5 minutes.
Select
Residual Cool – For cooling system efficiency, this tells the fan to keep running for up to two
minutes after the cooling system has shut down.
60Sec
Balance Points – This choice only appears when the 1st stage is a heat pump. Low and High
balance points are selected. The low balance point prevents the heat pump from being used
Select
when it is least efficient. The high balance point prevents the second stage heat (furnace or
strip) from activating when the heat pump is most efficient.
Outdoor setpoint temperature ranges are:
Low Setpoint : -20ºF to 75ºF (-29ºC to 24ºC)
High Setpoint : 0ºF to 75ºF (-18ºC to 24ºC)
(For more information, see What are balance points? in FREQUENTLY ASKED QUESTIONS on
page 28.)