Inactive Port Reasons And Actions - McDATA Sphereon 4300 Installation And Service Manual

Fabric switch
Hide thumbs Also See for McDATA Sphereon 4300:
Table of Contents

Advertisement

12
A connection is not allowed because of a SANtegrity authentication
failure. At the EFCM Basic Edition interface, modify the IP address
access control list, product-level authentication settings, port-level
authentication settings, and challenge handshake authentication
protocol (CHAP) sequence to ensure device access to the product.
Refer to the McDATA EFCM Basic Edition User Manual (620-000240)
for instructions.
Was the maintenance action successful?
NO
YES
The product port is operational. Exit MAP.
Contact the next level of support. Exit MAP.
13
As indicated by event code 083, a port is set to an inactive state.
a. At the Event Log, examine the first two bytes of event data.
b. Byte 0 specifies the port reporting the problem. Byte 1 specifies
the inactive reason as listed in

Inactive Port Reasons and Actions

Table 3-10
Byte 1
Inactive Port Reason
02
Feature key not enabled.
03
Switch speed conflict.
04
Optics speed conflict.
14
A port is inactive because Flexport Technology is disabled. Install the
Flexport Technology PFE key to enable N_Port capability. Refer to
Install PFE Keys
(Optional). Exit MAP.
15
A port is inactive because the:
Port cannot operate at the product (backplane) speed.
Optical transceiver does not support the configured port speed.
Maintenence Analysis Procedures
Table
3-10.
Action
Go to
step
Go to
step
Go to
step
Maintenance Analysis Procedures
14.
15.
15.
3-23

Advertisement

Table of Contents
loading