McDATA Sphereon 4300 Installation And Service Manual page 76

Fabric switch
Hide thumbs Also See for McDATA Sphereon 4300:
Table of Contents

Advertisement

Maintenence Analysis Procedures
McDATA Sphereon 4300 Fabric Switch Installation and Service Manual
3-12
2
Ensure the product is connected to facility power. Inspect the product
for indications of being powered on, such as:
An illuminated PWR LED (green) or ERR LED (amber).
Illuminated LEDs adjacent to Fibre Channel ports.
Audio emanations and airflow from cooling fans.
Is the product powered on?
YES
NO
A power distribution problem is indicated. Go to
Power Distribution
3
A product-to-PC link problem (Internet too busy or IP address typed
incorrectly) or an Ethernet port failure is indicated.
a. Wait approximately five minutes, then attempt to login to the
product.
b. At the Netsite field (Netscape Navigator) or Address field
(Internet Explorer), type http://xxx.xxx.xxx.xxx, where
xxx.xxx.xxx.xxx is the product IP address obtained in
0000: Start
MAP. The Username and Password Required dialog
box appears.
c. Type the user name and password obtained in
MAP
and click OK. If the EFCM Basic Edition interface does not
open, wait five minutes and perform this step again.
Is the EFCM Basic Edition interface operational?
NO
YES
The Internet connection is restored. Exit MAP.
4
The IP address defining the product to the interface is incorrect or
unknown. An asynchronous RS-232 modem cable and maintenance
terminal (desktop or notebook PC) with a Windows-based operating
system and RS-232 serial communication software (such as
ProComm Plus or HyperTerminal) are required. To determine the IP
address:
Analysis. Exit MAP.
MAP 0100:
MAP
MAP 0000: Start

Advertisement

Table of Contents
loading

Table of Contents