Map 0300: Loss Of Browser Pc Communication; Map 200 Byte 0 Fru Codes - McDATA Sphereon 4300 Installation And Service Manual

Fabric switch
Hide thumbs Also See for McDATA Sphereon 4300:
Table of Contents

Advertisement

MAP 0300: Loss of Browser PC Communication

b. Byte 0 specifies failed FRU. Byte 1 specifies the slot number of
the failed FRU (00 for nonredundant, 00 or 01 for redundant) as
listed in
Table
3-5.

MAP 200 Byte 0 FRU Codes

Table 3-5
Byte 0
Failed FRU
02
CTP card.
05
Fan module.
06
Power supply.
3
As indicated by event code 411, POST/IPL diagnostics detected a
firmware failure and performed an online dump. All Fibre Channel
ports reset after failure and devices momentarily logout, login, and
resume operation. Perform a data collection and contact the next
level of support. Refer to
This MAP describes fault isolation for the product to browser PC
Internet connection (EFCM Basic Edition interface). The failure
indicator is a Page cannot be found, Unable to locate the server,
HTTP 404 - file not found, or similar message.
NOTE: Upon restart, it may take up to five minutes for the Internet
connection to activate. This delay is normal.
1
The browser PC cannot communicate with the product because:
The product-to-PC Internet link could not be established.
AC power distribution for the product failed or AC power was
disconnected.
The product CTP card failed.
Continue to the next step.
Maintenence Analysis Procedures
Action
Replace the switch. Exit MAP.
Replace the switch. Exit MAP.
Replace the switch. Exit MAP.
Collect Maintenance
Data. Exit MAP.
Maintenance Analysis Procedures
3-11

Advertisement