L. Removal and Replacement of Pump Motor
1) Turn off the power supply.
2) Remove the front panel.
3) Remove the three screws and the float switch assembly.
4) Disconnect the pump motor wiring connector and the ground wire.
5) Disconnect the hoses attached to the pump motor assembly.
6) Remove the four screws and the pump motor.
7) Install the new pump, and replace the removed parts in the reverse order of which they
were removed. Be sure to connect the ground wire.
8) Turn on the power supply, and check for leaks.
9) Replace the front panel in its correct position.
51