The icemaker must be cleaned & sanitized at least once a year.
Cleaning Prep:
1
Remove the Front Panel, move the
OFF. After 3 min., move the
replace the Front Panel.
2
After 3 min., remove the Front Panel, move the
control switch
to OFF. This removes the cubes from
the evaporator.
3
Remove all ice from the dispenser unit/ice storage bin
ATTENTION! IF ON DISPENSER, turn off the dispenser
power supply after dispensing all the ice.
Cleaning:
Front of Icemaker
(KML-351MAH shown)
CONTROL SWITCH
SERVICE SWITCH
4
Remove the Front Panel, move the
DRAIN. Move
control switch
the Front Panel.
5
After 2 minutes, remove the Front Panel, move the
control switch
to OFF.
6
Dilute Hoshizaki Scale Away with warm water (see Table below).
Remove the Front Insulation Panel and pour cleaning solution
into the water tank. Replace the Front Insulation Panel.
#51007 | 8.22.2016
Cleaning & Sanitizing
control switch
to
control switch
to ICE, then
service switch
to
to SERVICE. Replace
 continued on the back...
Tech Support: 1.800.233.1940
3
min.
3
min.
.
Top
Side
After 2 min.
KML-250MAH, MWH
KML-351MAH, MWH
KML-451MAH, MWH
KML-631MAH, MWH, MRH
ATTENTION!
Do not leave icemaker
unattended when panels are off
AMMONIA
Cleaners
Sanitizing:
 Dilute 5.25% chlorine
bleach* with warm water
(see Table below)
KML-451 and smaller
Bleach
1 fl. oz (30 ml)
Warm Water
2 gal. (7.6 l)
KML-631
Bleach
1.25 fl. oz (37 ml)
Warm Water
2.5 gal. (9.5 l)
* Use bleach without additives.
 Remove the front insulation
panel
 Pour the sanitizing solution
into the water tank
 Replace the front insulation
panel
 Move
service switch
to
WASH and
control switch
SERVICE, replace the front
panel
 After 15 minutes, remove
front panel
 Move
service switch
to DRAIN,
replace the front panel
 After 2 minutes, remove
front panel
 Move
control switch
to OFF
14
15
16
to
17
Page 1

Advertisement

loading

Summary of Contents for Hoshizaki KML-250MAH

  • Page 1 After 2 min. control switch to OFF. Dilute Hoshizaki Scale Away with warm water (see Table below).  After 2 minutes, remove Remove the Front Insulation Panel and pour cleaning solution front panel into the water tank. Replace the Front Insulation Panel.
  • Page 2 Need Service or Repair? Locate your closest Hoshizaki Certified Service Tech: hoshizakiamerica.com/locate-service-rep  sanitizing continued… Move the service switch to WASH, and the control switch to SERVICE. Replace Front Panel. RINSE 1: (Steps 18-21) After 30 minutes, remove Front Panel, move the ...

This manual is also suitable for:

Kml-250mwhKml-351mwhKml-451mahl kml-451mwhKml-631mahKml-631mwhKml-631mrh