Appendix A Event Notification Message List
A.2 Message List
A.2.6
Sense Codes
This section describes the sense codes that are notified to the server.
Sense code
SK
02
04
04
04
04
04
04
04
04
04
04
04
04
04
04
04
04
04
04
04
04
04
ETERNUS DX80 S2/DX90 S2 Disk storage system User's Guide -Operation-
ASC
ASCQ
04
00
The device is in Not Ready status.
F1
01
CM is disconnected.
F1
0B
CM memory is disconnected.
F1
0C
CM BUD is disconnected.
F1
0D
CM FAN is disconnected.
F1
10
CA is disconnected.
F1
11
CA Port is disconnected.
F1
1A
CA SFP is disconnected.
F1
1C
CA SFP+ is disconnected.
F1
1D
CA SFP+ is disconnected.
F1
1F
CA SFP is disconnected due to an SFP type that
cannot be recognized.
F1
2A
CM QSFP is disconnected.
F1
80
3.5" HDD is disconnected.
F1
81
2.5" HDD is disconnected.
F1
84
3.5" SSD is disconnected.
F1
85
2.5" SSD is disconnected.
F1
88
Drive is disconnected because an error occurred dur-
ing the Write check of the disk patrol.
F1
90
IOM is disconnected.
F1
91
IOM Port is disconnected.
F1
9A
IOM QSFP is disconnected.
F1
D2
DPSU is disconnected.
F1
DA
CE or DE exhaust temperature error is detected.
Copyright 2011 FUJITSU LIMITED
Description
132
Remarks
This sense code is notified when "Not
Ready" is enabled for Error Severity
Level in the event notification setting.
They are not notified during mainte-
nance operations.
These sense codes are notified when
"Parts error" is enabled for Error
Severity Level in the event notification
setting.
They are not notified during mainte-
nance operations.
These sense codes are notified when
"HDD/SSD error" is enabled for Error
Severity Level in the event notification
setting.
They are not notified during mainte-
nance operations.
These sense codes are notified when
"Parts error" is enabled for Error
Severity Level in the event notification
setting.
They are not notified during mainte-
nance operations.
This sense code is notified when
"Sensor (Temperature) Error" or "Parts
error" is enabled for Error Severity
Level in the event notification setting.
They are not notified during mainte-
nance operations.
P3AM-4842-01ENZ0