Appendix A Event Notification Message List
A.2 Message List
A.2.2
Error Messages
This section describes the messages that are sent when the severity is Error for each type of
event.
■
Error message list
●
When the event type is "P"
The following messages are sent when components fail or degrade or when a temperature
error is detected.
Event type
P 01SSMM00 2
P 02SSMM0p 2
P 03SSMM0v 2
P 04SSMM00 2
ETERNUS DX80 S2/DX90 S2 Disk storage system User's Guide -Operation-
SNMP Trap
Trap
code
TrapItemID
No.
0100MM00
0200MM0p
0300MM0v
0400MM00
Copyright 2011 FUJITSU LIMITED
Upper: Message
Trap
Sensor
Lower: Description
Info
-
Controller Module#m(zz) Fault
<pppppppppppp ssssssssss rrrrr>
CM is disconnected.
SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (DX80S2 or DX90S2)
pp...: Component number
ss...: Serial number
rr...: Version
-
Controller Module#m(zz) DMA PORT#p Fault
<pppppppppppp ssssssssss rrrrr>
CM DMA port is disconnected.
SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (DX80S2 or DX90S2)
p: Port number (0 – 1)
pp...: Component number
ss...: Serial number
rr...: Version
-
Controller Module#m(zz) BIOS#v Fault
<pppppppppppp ssssssssss rrrrr>
CM BIOS is disconnected.
SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (DX80S2 or DX90S2)
v: Device number (0 – 1)
pp...: Component number
ss...: Serial number
rr...: Version
-
Controller Module#m(zz) RTC Fault
<pppppppppppp ssssssssss rrrrr>
CM RTC is disconnected.
SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (DX80S2 or DX90S2)
pp...: Component number
ss...: Serial number
rr...: Version
101
Remarks
These messages
are notified when
"Parts error" is
enabled for Error
Severity Level in
the event notifica-
tion setting. They
are not notified
during mainte-
nance operations.
P3AM-4842-01ENZ0