Appendix A Event Notification Message List
A.2 Message List
Event type
code
J 05SSMM00
J 06SSMM0v
J 08SSMMvp
J 09SSMMvp
J 0ASSMMvp
ETERNUS DX80 S2/DX90 S2 Disk storage system User's Guide -Operation-
SNMP Trap
Trap
TrapItemID
(*1)
No.
5
0500MM00
0
5
0600MM0v
0
5
0800MMvp
0
5
0900MMvp
0
5
0A00MMvp
0
117
Copyright 2011 FUJITSU LIMITED
Upper: Message
Lower: Description
Controller Module#m(zz) NVRAM Warning
<pppppppppppp ssssssssss rrrrr>
CM NVRAM error is detected.
SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (DX80S2 or DX90S2)
pp...: Component number
ss...: Serial number
rr...: Version
Controller Module#m(zz) EXP#v Warning
<pppppppppppp ssssssssss rrrrr>
CM EXP error is detected.
SS: Component subtype
MM: CM module ID (10 – 11)
v: EXP number (0)
m: CM number (0 – 1)
zz: Model name (DX80S2 or DX90S2)
pp...: Component number
ss...: Serial number
rr...: Version
Controller Module#m(zz) DI Port#P Warning
<pppppppppppp ssssssssss rrrrr>
CM DI port error is detected.
SS: Component subtype
MM: CM module ID (10 – 11)
v: Device number (0)
p: Device port number (0 – 1)
m: CM number (0 – 1)
zz: Model name (DX80S2 or DX90S2)
P: Port number (0 – 1)
pp...: Component number
ss...: Serial number
rr...: Version
Controller Module#m(zz) EXP#v In Port#p
Warning <pppppppppppp ssssssssss rrrrr>
CM EXP IN port error is detected.
SS: Component subtype
MM: CM module ID (10 – 11)
v: EXP number (0)
p: Port number (0 – 1)
m: CM number (0 – 1)
zz: Model name (DX80S2 or DX90S2)
pp...: Component number
ss...: Serial number
rr...: Version
Controller Module#m(zz) EXP#v Out Port#p
Warning <pppppppppppp ssssssssss rrrrr>
CM EXP OUT port error is detected.
SS: Component subtype
MM: CM module ID (10 – 11)
v: EXP number (0)
p: Port number (0)
m: CM number (0 – 1)
zz: Model name (DX80S2 or DX90S2)
pp...: Component number
ss...: Serial number
rr...: Version
Remarks
These mes-
sages are noti-
fied when
"Parts warn-
ing" is enabled
for Warning
Level in the
event notifica-
tion setting.
They are not
notified during
maintenance
operations.
P3AM-4842-01ENZ0