Table C-9. Group AC_2_2MV: Flatness Constants, 2.2 mV Range
Name
F1_2_2MV
F2_2_2MV
F3_2_2MV
F4_2_2MV
F5_2_2MV
F6_2_2MV
F7_2_2MV
Table C-10. Group DC_7MV: DC Constants, 7 mV Range
Name
Default
DI_7MV
1000.0
OF_7MV
0.0
Table C-11. Group ZC_7MV: More DC Constants, 7 mV Range
Name
Z_7MV
0.0
SHO_7MV
0.0
IA_7MV
0.00316228
Table C-12. Group AC_7MV: Flatness Constants, 7 mV Range
Name
F1_7MV
F2_7MV
F3_7MV
F4_7MV
F5_7MV
F6_7MV
F7_7MV
Table C-13. Group DC_22MV: DC Constants, 22 mV Range
Name
Default
DI_22MV
500.0
OF_22MV
0.0
Default
Function
1.0
(10 Hz)
1.0
(1 kHz)
1.0
(20 kHz)
1.0
(300 kHz)
1.0
(500 kHz)
1.0
(800 kHz)
1.0
(1 MHz)
Function
Basic gain (Ref. DAC to input ratio)
Full scale calibrated DC offset
Default
Function
Zero calibrated DC offset
Shunt input DC offset
Rough gain (input to A/D ratio)
Default
Function
1.0
(10 Hz)
1.0
(1 kHz)
1.0
(20 kHz)
1.0
(300 kHz)
1.0
(500 kHz)
1.0
(800 kHz)
1.0
(1 MHz)
Function
Basic gain (Ref. DAC to input ratio)
Full scale calibrated DC offset