Section 4: Operation
COLD WEATH
ER
OPERATION
Under certain weather conditions (temperatures below
40°F [4°C] and a high clew point), your generator may
experience icing of the carburetor and/or the crankcase
breather system.
Build a structure that wilt enclose three sides and top of
generator:
I.
Make sure entire muffler-side of generator is exposed.
Note that your generator may appear different from
that shown in Figure 8.
G EN ERATO R ADAPTER
CORD
SET
The generator is equipped with a 25' generator adapter cord
set designedfor a 240Volt, 30 Amp grounded neutral circuit
(Figure9).The generator adapter cord set provides a
convenient supply of emergencypower into your dwelling so
that your generator can be operated safelyoutside.
J
2.
Ensure a minimum of two feet clearance between open
side of box and nearest object.
3.
Face exposed end away from wind and elements.
4.
Enclosure should hold enough heat created by
generator to prevent problems.
,_
DANGER
The maximum load on each outlet is 20 Amps.The
maximum total load on both yellow wire outlets or both
black wire outlets is 30 Amps.
NOTE:
Follow all safety precautions
when connecting any
extension cord or device to the generator.
Operate
generator
ONLY outdoors.
Keep at least 2 feet of clearance on all sides of generator
for
adequate ventilation.
DO NOT operate generator inside any building or enclosure,
including the generator compartment of a recreational vehicle (RV).
Remove generator
from shelter when temperature
is above
40°F [4°C].