NOTE: DuringAUTOmode,theunit operates i n Heatingmodewhen!heroomtemperature i s below68°F,
Dehumidifier modewhentheroomtemperature i s between 68 F to 80 F.
And Air Conditioner
mode when
the room temperature
is above
80 F.
Emerqency Condensate
Holdinq Tank
When the room temperature
is low and the indoor humidity
is high, the air conditioner
may not be able to
evaporate
some of the moisture
fast enough.
When this happens,
the water will accumulate
in an emergency
condensate
tank inside the unit. Once the emergency
condensate
tank is full, the unit will automatically
shut
offand
the"
_
"will
appear
on the control
panel display.
To empty the condensate
tank, pull the drain plug
at the bottom
back of the unit. You will need a small pan, approximately
1" high to catch the water coming out
of the condensate
tank. Once the condensate
tank is drained,
the unit will begin working
within a few minutes.
The emergency
condensate
tank is approximately
1.5 Liters of water. Another
option is to purchase
a small
hose from a hardware
store that can fit around the 5/8" drain plug on the back of the unit and drain the unit into
a gravity
drain or larger pan for continuous
drainage.
It is not advised
to use continuous
drainage
when the
room temperature
is higher than 90°F.