Warning: If the information in these instructions is not followed
exactly, a fire or explosion may result causing property damage,
personal injury or loss of life.
Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
What To Do If You Smell Gas:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
 Installation and service must be performed by a qualified installer, service agency or
the gas supplier.
Gas Conver-
sion Instruc-
tions
For models:
H34D
Check local codes and
read all instructions
prior to conversion.
Leave this manual with
the owner.

Advertisement

loading

Summary of Contents for Montigo H34D

  • Page 1 Gas Conver- sion Instruc- tions For models: H34D Warning: If the information in these instructions is not followed Check local codes and  exactly, a fire or explosion may result causing property damage, read all instructions personal injury or loss of life.
  • Page 2: Table Of Contents

    General Information ..............2 This gas conversion kit contains the necessary components for field conversion of an approved Montigo fireplace from Natural Gas (NG) Parts list ..................2 to Liquid Propane (LP).This kit is approved for use with the following...
  • Page 3: Conversion

    Gas Conversion Kit Gas Conversion Instructions Conversion CAUTION - Before you begin: Unscrew the coupling assembly from the pan base. The burner orifice is located at the top end of coupling. Unscrew it and Shut off gas at the shut-off valve and disconnect the electrical install the new orifice from the conversion kit to convert to the supply (if used).
  • Page 4: Converting The Main Gas Control Regulator

    Gas Conversion Kit Gas Conversion Instructions Checking the Gas Pressure Install the new orifice from the conversion kit to convert to the To check the Inlet and Manifold gas pressures, a Water Column Pres- pilot to the new gas. Tighten the orifice securely with an allen sure Gauge with 5/16"...
  • Page 5: Operation

    Gas Conversion Kit Operating Instructions For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot. When lighting the pilot, follow If you cannot reach your gas supplier, call the Fire De- ...
  • Page 6 XG0675 Rev. 00 - 12/2003 Montigo Del Ray Corp. Canadian Heating Products Inc. Ferndale, WA 98248 Langley, BC V4W 4A1...