Command And Response Examples; Serial Command List - Runco 3Dimension D-113d Installation & Operation Manual

Full-hd private cinema projection system 3dimension series
Table of Contents

Advertisement

Here are some examples of serial commands and their responses:
Command
Power query when
(PWR?) [CR]
unit is powered on
Set power to 0 (off)
(PWR=0) [CR]
Increment bright-
(BRT+) [CR]
ness from 24 to 25
Invalid command
(ZZZ=0) [CR]
Invalid parameter
(CON="Some string")
(received string,
[CR]
expected integer)
Table 6-1 lists all supported commands.
Table 6-1. Serial Commands
Setting
Advanced Color Temp Auto Color
Enable
Advanced Color Temp Diagnostic
Color
PCE Blue x
PCE Blue y
Adjustment Mode
PCE Green x
PCE Green y
Apply Image Alignment Values
Advanced Color Temp Mode
Enable
Auto New Firmware Check
Auto Power Off Enable
Auto Power Off Timer
Auto Perform Upgrade
D-113d Projection System Installation/Operation Manual
Command Data
Command
Read/
Code
Write
AAC
R/W
AAD
R/W
ABX
R/W
ABY
R/W
ADJ
R/W
AGX
R/W
AGY
R/W
AIA
R/W
AME
R/W
ANF
R/W
APE
R/W
APT
R/W
APU
R/W
Response
(0;PWR=1) [CR]
(0;PWR=0) [CR]
(0;BRT=25) [CR]
(1;ZZZ=0) [CR]
(9;CON="Some string")
[CR]
Inc/
Min
Max
Dec
Value
Value
No
0
1
No
0
6
Yes
-100
100
Yes
-100
100
No
0
2
Yes
-100
100
Yes
-100
100
No
0
1
No
0
1
No
0
1
No
0
1
Yes
1
24
No
0
1
105
Command and Response
Examples

Serial Command List

String?
Notes
No
0 = Off; 1 = On
No
0 = White
1 = Red
2 = Green
3 = Blue
4 = Yellow
5 = Cyan
6 = Magenta
No
No
No
0 = Both
1 = Left
2 = Right
No
No
No
0 = Off; 1 = On
No
0 = Off; 1 = On
No
0 = Off; 1 = On
No
0 = Off; 1 = On
No
No
0 = Off; 1 = On
External Control

Advertisement

Table of Contents
loading

This manual is also suitable for:

3dimension d-113d/cinewide with autoscope

Table of Contents