Removal And Replacement Of Fan Motor; Removal And Replacement Of Control Water Valve - Hoshizaki F-500BAF Service Manual

Self-contained flaker
Hide thumbs Also See for F-500BAF:
Table of Contents

Advertisement

7. Removal and Replacement of Fan Motor

1) Unplug the icemaker.
2) Remove the panels.
3) Remove the wire connectors from the fan motor leads.
4) Remove the fan motor bracket and fan motor.
5) Install the new fan motor.
6) Replace the fan motor bracket and the wire connectors.
7) Replace the panels in their correct position
8) Plug in the icemaker.

8. Removal and Replacement of Control Water Valve

1) Unplug the icemaker.
2) Remove the panels.
3) Close the water supply line shut-off valve.
4) Disconnect the terminal from the control water valve.
5) Loosen the fitting nut on the control water valve inlets, and remove the control water
valve. Do not lose the packings inside the fitting nut.
6) Remove the water supply hose from the control water valve.
7) Install the new control water valve.
8) Assemble the removed parts in the reverse order of the above procedure.
9) Open the water supply line shut-off valve.
10) Check for water leaks.
11) Replace the panels in their correct position.
12) Plug in the icemaker.
40