Optional Accessories

Table 1-2 lists optional accessories for the Calibrator.
Model
5320CASE
Transit case for 5320A Calibrator
Y5320
Rack mount kit for mounting a 5320A in a standard 19 inch rack.
5320A-LOAD
Load resistor adapter for hipot leakage current calibration

General Specifications

Warm-Up Time .................................................. 30 minutes
Specifications Confidence Level..................... 99 %
Specifications Interval.................................1 year
Temperature Performance
Operating Temperature .................................. 18 to 28 C
Calibration Temperature (tcal) ........................ 23 C
Temperature Coefficient ................................. Temperature coefficient for temperature outside of Tcal 5 C between
Storage Temperature...................................... -20 to +70 C
Relative Humidity (operating) .......................... <70 % to 28 C
Altitude
Operating ........................................................ 3,050 m (10,000 ft.)
Storage ........................................................... 12,200 m (40,000 ft.)
Dimensions ....................................................... 450 mm X 480 mm X 170 mm (17.7 in. X 18.9 in. X 6.7 in.)
Weight ................................................................ 18 kg (39.7 lb)
Power Line......................................................... 115/230 V ac (50/60 Hz) 10 %
Power Consumption ......................................... 150 VA Maximum
Safety Class ...................................................... Class I, Bonded Enclosure
Electrostatic Discharge .................................... This instrument meets class I for ESD requirements per EN 61326
W Fuse Protection
AC mains input ............................................... 2 A, 250 V for 230 V, Time delay (T2L250 V – 5 x 20 mm)
RCD input ....................................................... 3.15 A, 250 V, Fast (F3.15L250V – 5 x 20 mm)
Meter amps (A) input ...................................... 20 A, 500 V, Time delay (T20L500V – 6.3 x 32 mm)
Loop/Line impedance input............................. 4 A, 250 V, Time delay (T4L250V – 6.3 x 32 mm)
Leakage current input ..................................... 100 mA, 150V, Fast (F100mL150V – 5 x 20 mm)
Table 1-2. Optional Accessories
Description
+5 C to +40 C is 0.1 x / C
(Criteria A)
4 A, 250 V for 115 V, Time delay (T4L250 V – 5 x 20 mm)