Operating
Instructions
This water heater is equipped with an electrically operated vent-
ing system and a standing pilot. For the burner to come on, the
water heater thermostat must call for heat. Then the system will
begin sequencing, each section proving itself before gas is
allowed to flow to the burner.
BLOWER MOTOR
BEFORE THE WATER HEATER WILL OPERATE:
1. The control system must
be connected
to a 1101120
volt
power supply. The control system has an overall rating of 2
amps. The water heater
must be securely and adequately
grounded
in accordance with local codes and with the latest
edition of the National
Electrical Code ANSI/NFPA
70.
2. The ON/OFF
toggle switch, located on the control box
above the thermostat must be in the "ON" position for the
electrical control system to operate allowing the gas portion
to operate (ignite burner).
3. The pilot must be lit. See Lighting instructions on page 23
of this manual or located adjacent to the thermostat on the
water heater.
4. The gas control knob located on the thermostat must be
turned to the "ON" position for the gas to be able to flow.
5. The venting manual reset switch must be in the closed posi-
tion. See 'Vent'ng Manual Reset Switch' "n the "For Your
Information Section".
6. There is a non-resettable hi-limit switch in the thermostat,
which m_t be good (dosed) for the thermostat to be oper-
ated. See High Temperature Shut Off System in the For
Your Information Section".
OPERATION
When
the thermostat
calls for heat, gas is allowed to flow to a
(Normally
open) pressure switch dosing
it. An electrical circuit
is then made to the blower, turning
it on. The indicator
light
located on the control box will come on. When
the blower has
achieved sufficient venting, the air pressure switch will close and
the indicator
light will go off. A 120 volt circuit will be com-
pleted through
the venting
manual
reset switch and on to the
120 volt gas valve located just below the thermostat.
The
120
vokgas
valve will open allowing gas to flow to the burner. The
standing pilot will establish a main burner flame.
RESETSWITCH
DRAFT HOOD
AIR PRESSURE
ONIOFF SWITCH
/
SWITCH
GAS CONTROL
KNOB
GAS THERNOSTAT
120V GAS VALVE
21