Hotpoint RA720 Owner's Manual & Installation Instructions page 19

20" and 24" compact electric ranges
Table of Contents

Advertisement

Available languages

Available languages

Installation
Instructions
_-]
3-WIRE
POWER CORD
INSTALLATION
A
r_
WA RN!NG: The n eutral
or ground
wire
of the power cord must be connected to the
neutral terminal located in the center of the
terminal
block. The power leads must be
connected to the lower left and the lower right
terminals
of the terminal
block.
Remove the 3 lower terminal
screws from the
terminal
block. Insert the 3 terminal screws
through
each power cord terminal ring and
into the lower terminals of the terminal
block.
Be certain that the center wire (white/neutral)
is connected
to the center lower position of
the terminal block. Tighten screws securely
into the terminal
block.
DO NOT remove the ground
strap
connection.
Terminal
block
_¢/
(appearance
may vary)
Ground plate
Neutral
terminal
Ground
strap
Power cord
r_
Skip to step 8 and proceed with the
installation.
[_]
4-WIRE
POWER CORD
INSTALLATION
,A
D
WA RNING: The n eutral wire o fthe
supplycircuit must be connectedto theneutral
terminal located inthelowercenter ofthe
terminal block. The power leads must be
connectedtothe lowerleft a nd thelowerright
terminals o ftheterminal block. T he 4th
groundingleadmust be connectedtotheframe
oftherangewiththeground plate and the
ground screw.
Remove the 3 lower terminal screws from the
terminal block. Remove the ground screw and
ground plate and retain them.
r_
cut and discard the ground strap. DO NOT
DISCARDANY SCREWS.
D
[53
Before
//
_
Terminal ...___
- !;
Cut and discard
.._
the ground strap
Insert the one ground screw into the power cord
ground wire terminal ring, through the ground
plate and into the frame of the range.
Insert the 3 terminal screws (removed earlier)
through each power cord terminal ring and into the
lower terminals of the terminal block. Be certain that
the center wire (white/neutral)is connected to the
center lower position of the terminal block. Tighten
screws securely into the terminal block.
Ground strap
terminal
After
Terminal
block
Ground
screw
Neutral
terminal
Ground plate
(grounding
to range)
r_
Skipto step 8 and proceed with the installation.
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ra724Ra820Ra824

Table of Contents