Fedders 23-23-0321N-002 Installation & Operation Manual page 5

Room air conditioners for double-hung windows 5,000-18,000 btu's
Table of Contents

Advertisement

Available languages

Available languages

3
ii
El
1/4"
Lower window
sash
SIDE VIEW
5. Adjust leveling bolt so curved top of support
channel is 1/4" below top of window
sill.
This downward tilt toward outside prevents
water from entering inside of room (Fig. 7).
6. Repeat steps 2 through 5 for second support
channel
if required.
1. Keeping a firm grip on air conditioner,
care-
fully center air conditioner
in window
open-
ing with the bottom bar sitting behind
window siN. Be sure cabinet maintains an
outward pitch. Air conditioner
should slant
slightly downward on the outside as shown
by haft a bubble off on a carpenter's level.
This outward pitch prevents water from
entering the room (Fig,. 8).
8. Close window
until it touches behind air
conditioner
top bar. Slide finer panels out-
ward until they touch window sash tracks.
(Do not release grip on air conditioner
until
lower window
sash is in final position)
(Fig. 9).
!
k
._
3
k.
2
9
%"
-j
(
)
Window
0
0
sill _lllllllllllllllllllllll_iil . ......
_
Bottom bar
\
Support
channel
SIDE VIEW
Caution: Do not drill a hole in bottom pan. Unit is designed to operate with approximately
1/2" of water in bottom pan.