Service
Instructions
Tosavetime and expense,check the following before
calling an authorizedservicecompany.
Insufficient
Cooling
Turn Master Control to OFF.
Shut all windows and doors in room.
Remove any obstructions from inside
and outside cabinet louvers.
Close Air Exchanger (available on
most units).
Inspect filter and dean if dirty.
Turn Thermostat and Master Controls
to coolest settings.
Under certain conditions the cooling coils directly
behind the filter, may ice up and block the airflow.
This is a common occurrence in air conditioners
caused when the outside temperature drops below
70°F (21 °C) while the humidity remains high.
If this happens, simply turn the unit off and allow
the ice to melt, then resume normal operation.
Insufficient
Heating-
Heating
Models
Only
Turn Master Control to OFF.
Shut all windows and doors in room.
Remove any obstructions from inside
and outside cabinet louvers.
Turn Thermostat and Master Controls
to warmest settings.
Unit
Fails
to Start
Turn Master
Control
to OFF.
Replug
line cord
plug
into outlet
to be sure
electrical
contact
is being
made.
(If firm
contact
is not being
made,
outlet
may have
to be replaced).
Turn Master
Control
to HIGH
FAN.
If air
circulating
fan does not operate,
check
house
circuit
breaker
(or fuses).
For
Models
Installed
in
North
America
- If Service
or Parts
are
Required
First, make the recommended checks. If it appears
that service or parts are still required, see your
room air conditioner
warranty "How to Obtain
Warranty Service or Parts".
For
Models
Installed
Outside
North
America
For room air conditioners
purchased for use out-
side North America, the manufacturer does not
extend any warranty either expressed or implied.
Consult your local dealer for any warranty terms
extended by the importer in your country.
Room
Air
Conditioner
Warranty
(Within
the 48 cont_uous
Uni_d
S_
sta_
of _waii,
the District
of Columbia,
Puerto
Rico and Canada)
Full (One Year) Parts and Labor Warranty
During
the first year after the date of original
pur-
chase,
Fedders
North
America
will,
through
its
authorized
servicers
and free of charge
to the
owner
or any
subsequent
user, repair
or replace
any parts which
are defective
in material
or work-
manship
due to normal
use. Ready access to the
air conditioner
is the responsibility
of the owner.
Limited (Five Year)SealedSystemWarranty/
(Two Year)FanMotor Parts Warranty
In addition to the full (one year) [)arts an(] labor
warranty described above, Fedders North America
will, through its authorized servicers or parts dis-
tributors, exchange sealed system parts (consisting
of compressor, evaporator, condenser, and inter-
connecting tubing) during the second year through
fifth year, and the fan motor during the second
year, both from the original date of purchase,
providing the parts are defective in material or
workmanship.
Transportation, handling, or labor
costs to diagnose, repair or replace such defective
parts are not covered by this limited parts
warranty and are the owner's responsibility.
Note: In the event of any required
pm!s replacement
within
the
period of this warranty,
Fedders North America
replacement
par_s shall be u_ed and will be warranted
only for the period
remaining
on the original
wam_nty.