Checking The Excitation Circuit; Checking The Stator Power Winding - Briggs & Stratton 1938 Operator's Manual

Table of Contents

Advertisement

Service
& Troubleshooting
Guide ' Home
Generator
Systems
__'ggs
_ s_o_o.
Checking
The
Access Requirements:
• Roof Removal
• Muffler Box Removal
• Fuel Line From Regulator Removal
Related
Fault Indications:
• Low Voltage ([ • • • ]) Three Blinks
Gain access to the capacitors as mentioned
above.
• Isolate The Capacitors
Excitation
Circuit
Page 46
Page 46
Page 47
NOTE:
Use the manufacturer's
instructions that
apply to the type of meter you are using. The rated
capacity is printed on the capacitors.
• . If a value discrepency is found:
• Replace Capacitor
Check Excitation Winding
(DPE) Resistance between wires
that were disconnected
from capacitors and lead into the
stator, as shown in figure 41.
ou,d
•. If resistance reading is OK:
• Re-install/replace
the capacitors
• Re-assemble the standby generator
enclosure.
Checking
The Stator
Power
Winding
Access Requirements:
• Roof Removal
• Muffler Box Removal
• Fuel Line From Regulator Removal
Related
Fault
Indications:
• Low Voltage ([ • • • ]) Three Blinks
Page 46
Page 46
Page 47
Gain access to the stator power winding leads as mentioned
above.
• Isolate the colored wires from the terminal
block.
• Measure the resistance value of the stator power
winding as shown in figure 42.
• • If not:
• Check for short-to-ground.
• • If none:
_- _Replace
Stator 1
See "Removing The Meccalte-Generator"
(Page 46).
I! 1091 109 Ohms+-5%
_,_....................................
_, .............................................................................................................
V should be measured.
•• If not:
• Check for short-to-ground.
"" If none:
_
l Replace Stator
43