When The Same Gain Is Used For Two Or More Axes; Slight Vibration Suppression Control - Mitsubishi Electric Melservo-J2-JR SERIES Instruction Manual

General-purpose ac servo general-purpose interface mr-j2-03a5
Table of Contents

Advertisement

7. ADJUSTMENT
7.4.5

When the same gain is used for two or more axes

(1) Machine condition
To perform interpolation operation with two or more axes of servo amplifiers, the position loop gains of
the axes are set to the same value.
(2) Adjustment procedure
1) To adjust the gains of each axis, adjust the gains of all axes in the adjustment procedures in
Sections 7.4.1 to 7.4.4.
2) Set
0
or
0
: Interpolation control
Parameter No.
No. 35
No. 37
No. 38
2
: No auto tuning
3) Match position loop gain 1 to the minimum value of each axis to make the gains of all axes equal.

7.5 Slight Vibration Suppression Control

The slight vibration suppression control mode is used to reduce servo-specific 1 pulse vibration at the
time of a stop. This mode produces an effect especially when the ratio of load inertia moment to servo
motor inertia moment is small (2 to 5 times). Note that when vibration is attributable to looseness (such as
gear backlash) or machine resonance, use the machine resonance suppression filter in parameter No.22.
The slight vibration suppression control mode should be used after real-time auto tuning or manual gain
adjustment.
Usage
First, perform real-time auto tuning or manual gain adjustment so that vibration falls within 2 to 3
pulses.
Set
1
in parameter No. 20 to enter the slight vibration suppression mode at the time of a stop.
2
in parameter No. 2.
The following parameter values change at the next start/stop.
Symbol
PG2
Position loop gain 2
VG2
Speed loop gain 2
VIC
Speed integral compensation
Make auto tuning invalid and set each gain manually.
Parameter No. 20
1
Name
Slight vibration suppression
control execution
7 - 10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-j2-03a5

Table of Contents