LAMP indicator
Indicator
display
Illuminated (red)
Flashing (red)
It is nearly time to
An abnormality has been detected in the lamp
Problem
replace the lamp
circuit.
mit.
• Does "REPLACE
• The power may
• There may be an
LAMP" appear on
have been turned
abnormality in the
Possible
the screen after
on straight away
lamp circuit.
cause
the projector is
after it was turned
turned on?
off.
Remedy
• This occurs when
the operation time
for the lamp unit is
nearing 1800
hours. (when
LAMP POWER
has been set to
"HIGH") Ask your
dealer or an
Authorised
Service Centre to
replace the lamp
unit.
Wait for a while
until the lamp unit
cools down before
turning the power
back on again.
• Turn off the MAIN
POWER switch by
following the
procedure given
on page 23, and
then contact an
Authorised
Service Centre.
NOTE:
• Be sure to turn off the MAIN POWER switch by following the procedure
given in "Turning off the power" on page 23 before carrying out any of the
procedures in the "Remedy" column.
• If the main power turns off after the TEMP indicator starts flashing, it
means that an abnormality has occurred. Please contact an Authorised
Service Centre so that the necessary repairs can be made.