Sharp AR-M256 Operation Manual page 84

Digital multifunctional system
Hide thumbs Also See for AR-M256:
Table of Contents

Advertisement

APPENDIX
Weight
Dimensions
Operating conditions
Noise level
Emission concentration
(measured according to
RAL-UZ62: Editon Jan.
2002)
*1 First copy time is measured with original on the document glass in full ready condition with fuser at operating temperature and
mirror motor at operating speed, actual time may vary based on environment conditions.
*2 The warm-up time may vary depending on the power-supply voltage, ambient temperature, and other operating conditions.
As a part of our policy of continuous improvement, SHARP reserves the right to make design and specification
Note
changes for product improvement without prior notice. The performance specification figures indicated are
nominal values of production units. There may be some deviations from these values in individual units.
82
Approx. 55 kg (121.3 lbs.) (Not includes toner cartridge)
623 mm (W) x 615 mm (D) x 786 mm (H)
(24-17/32" (W) x 23-13/64" (D) x 30-15/16" (H))
Temperature: 15°C to 30°C (59°F to 86°F), Humidity: 20% to 85%
Sound Power Level L
(1B=10dB)
wA
Copying: 6.3[B] (AR-M256)
Copying: 6.5[B] (AR-M316)
Standby: 3.2[B] (AR-M256, AR-M316)
Sound Pressure Level L
Copying: 47[dB(A)] (AR-M256)
Copying: 51[dB(A)] (AR-M316)
Standby: 16[dB(A)] (AR-M256, AR-M316)
Sound Pressure Level L
Copying: 50[dB(A)] (AR-M256)
Copying: 52[dB(A)] (AR-M316)
Standby: 16[dB(A)] (AR-M256)
Standby: 17[dB(A)] (AR-M316)
Noise emission measurement in accordance with ISO 7779.
3
Ozone:
0.02 mg/m
or less
3
Dust:
0.075 mg/m
or less
3
Styrene: 0.07 mg/m
or less
(bystander positions)
pA
(operator position)
pA

Advertisement