TROUBLESHOOTING AND MAINTENANCE
4
Close the front cover and side cover.
B: Misfeed in the fusing area
1
Open the bypass tray and the side
cover.
2
Press and pull it open gently on both
sides of the front cover.
3
Turn the roller rotating knob in the
direction of the arrow.
Roller rotating knob
4
Lift the fusing unit release levers and
carefully remove the misfed paper.
Fusing unit release levers
The fusing unit is hot. Do not touch
Warning
the fusing unit when removing
misfed paper. Doing so may cause a
burn or injury.
68
Make sure that the
misfeed message is
cleared.
5
If you were unable to remove the
misfeed in step 4, press down on the
fusing unit paper guide knob to open
the paper guide, and carefully remove
the misfed paper.
• Do not touch the photoconductive drum
Caution
(green portion) when removing the misfed
paper. Doing so may damage the drum
and cause smudges on copies.
• Take care not to let unfixed toner on the
misfed paper soil your hands or clothes.
6
Close the fusing unit paper guide and
press down on the fusing unit release
levers.
7
Close the front cover and side cover.
Make sure that the
misfeed message is
cleared.