swFwWriteActVals [swFwClassAreaTable]
Syntax
SwFwWriteVals
Access
Read-write
Status
Mandatory
Description
This applies or cancels the alarm value changes.
Note:
swFwDefaultChangedActs[swFwClassAreaTable]
Syntax
SwFwActs
Access
Read-only
Status
Mandatory
Description
Default action matrix for changed event.
swFwDefaultExceededActs [swFwClassAreaTable]
Syntax
SwFwActs
Access
Read-only
Status
Mandatory
Description
Default action matrix for an exceeded event. The exceeded value may be either above the
high-threshold or below the low-threshold.
MIB Reference Manual Version 3.0
For a read operation, the return value is always swFwCancelWrite.
The following are the custom alarm variables that can be modified.
•
swFwCustChangedActs
•
swFwCustExceededActs
•
swFwCustBelowActs
•
swFwCustAboveActs
•
swFwCustInBetweenActs
Changes to these custom alarm variables can be saved by setting this variable to
swFwApplyWrite.
Changes to these custom alarm variables can be removed by setting this variable to
swFwCancelWrite.
FCSwitch MIB Object Types
4