2
Fibre Alliance MIB Object Types
connUnitPortFCId [connUnitPortTable]
Syntax
Octet String of size 3
Access
Read-only
Status
Mandatory
Description
This is the assigned Fibre Channel ID of this port. This value is expected to be a Big Endian value
of 24 bits. If this is loop, then it is the ALPA that is connected. If this is an E_port, then it contains
only the domain ID left justified, zero filled. If this port does not have a Fibre Channel address,
return all bits set to 1.
Note:
connUnitPortSn [connUnitPortTable]
Syntax
Display String of size 0 to 79
Access
Read-only
Status
Mandatory
Description
The serial number of the unit (for example, for a GBIC). If this is not applicable, return empty
string.
Note:
connUnitPortRevision [connUnitPortTable]
Syntax
Display String of size 0 to 79
Access
Read-only
Status
Mandatory
Description
The port revision (for example, GBIC).
Note:
2-38
For an F_port, this is the Fibre Channel ID to which the connected N_port is assigned. For
an FL_port, this is the Fibre Channel ID of the FL_port (alpa = 0). For a U or E_port, this
is similar to F_port.
If GBIC is the serial ID, this returns the GBIC part number. Otherwise it returns a Null
value.
If GBIC is the serial ID, this returns the GBIC revision number. Otherwise it returns a Null
value.