2
Fibre Alliance MIB Object Types
If the addressed connUnit allows this operation to be performed to this port, the addressed port
performs a vendor-specific reset operation. Examples of these operations are:
•
•
•
•
bypassConnUnitPort:
If the addressed connUnit allows this operation to be performed to this port, the addressed port
performs a vendor-specific "bypass" operation. Examples of these operations are:
•
•
•
•
unbypassConnUnitPort:
If the addressed connUnit allows this operation to be performed to this port, the addressed port
performs a vendor-specific "unbypass" operation. Examples of these operations are:
•
•
•
•
offlineConnUnitPort:
If the addressed connUnit allows this operation to be performed to this port, the addressed port
performs a vendor-specific offline operation. Examples of these operations are:
•
•
•
•
onlineConnUnitPort:
If the addressed connUnit allows this operation to be performed to this port, the addressed port
performs a vendor-specific online operation. Examples of these operations are:
•
•
•
2-40
The Link Reset protocol.
The Loop Initialization protocol.
Re-synchronization occurring between the transceiver in the addressed port to the
transceiver that the port is connected to.
Transitioning from online to offline.
A request (NON-PARTICIPATING) command to the Loop port state machine.
Removal of the port from an arbitrated loop by a hub.
The Link Failure protocol.
A request (PARTICIPATING) command to the Loop port state machine.
Addition of the port to an arbitrated loop by a hub.
Disabling a port's transceiver
The Link Failure protocol
Request (NON-PARTICIPATING) command to the Loop port state machine removal of
the port from an arbitrated loop by a hub
Enabling a port's transceiver
The Link Failure protocol, request(PARTICIPATING) command to the Loop port state
machine
Addition of the port from an arbitrated loop by a hub.
Each implementation may choose not to allow any or all of these values on a SET.
If the Management Station uses in-band communication (FC-IP) with the switch, either of
the two following action may result in a loss of in-band communication with the switch:
•
Disabling the FC port that is connected to the Management Station.
•
Disabling the embedded port.
MIB Reference Manual Version 3.0