11) Remove the burner by undoing the 3
screws.
Burner Removed
12) Remove the burner tray by undoing the 4
screws.
Burner Tray Removed
®
Regency
L234 Direct Vent Gas Insert
13) Remove the rear log tray by undoing the 3
screws.
Rear Log Tray Removed
14) Remove the 12 screws that hold the valve
tray to the fi rebox and carefully pull out.
MAINTENANCE
Valve Removed
15) Replace the valve.
16) Reverse steps 14 - 1.