Carefully unpack oven and place in a work-accessible area as near to its final installed position as
possible.
Do not use the doors or their handles to lift the oven.

LOCATION

The equipment area must be kept free and clear of combustible substances.
When installed, minimum clearance from combustible construction must be 1"
4"
at the right side, and 6"
(10 cm)
construction must be 0"
oven may be stored on combustible floors.
The installation location must allow adequate clearances for servicing and proper operation.
The oven must be installed so that the flow of combustion and ventilation air will not be obstructed.
Adequate clearance for air openings into the combustion chamber must be provided. Make sure there
is an adequate supply of air in the room to allow for that required for combustion of gas at the oven
burners.
Do not permit fans to blow directly at the oven. Wherever possible, avoid open windows next to the
oven. Avoid wall-type fans which create air cross currents within the room.

INSTALLATION CODES AND STANDARDS

In the United States, Vulcan gas ovens must be installed in accordance with: 1) State and local codes;
2) National Fuel Gas Code, ANSI-Z223.1 (latest edition), available from American Gas Association,
1515 Wilson Boulevard, Arlington, VA 22209; 3) NFPA-96, Vapor Removal from Cooking Equipment
(latest edition); and 4) National Electrical Code, NFPA-70 (latest edition) available from National Fire
Protection Association, Batterymarch Park, Quincy, MA 02269.
In Canada, Vulcan gas ovens must be installed in accordance with: 1) Local codes; 2) CAN/CGA-
B149.1 Natural Gas Installation Code (latest edition) or CAN/CGA-B149.2 Propane Installation Code
(latest edition), available from Canadian Standards Association, 178 Rexdale Boulevard, Etobicoke,
Ontario, Canada M9W 1R3; and 3) Canadian Electrical Code, CSA Standard C22.2 No. 3, Electrical
Features of Fuel Burning Equipment (latest edition).

INSTALLING BASIC OVEN

The basic oven must be installed on legs or be mounted on a modular stand. Installations on concrete
bases or other supports restricting air circulation underneath the oven is not advisable and may void
the warranty.

Ovens Mounted on Casters

When the oven is mounted on casters, it must be installed with the
casters supplied, a connector complying with either ANSI-Z21.69
(latest edition) or CAN/CGA 6.16 (latest edition), and a quick-
disconnect device complying with either ANSI-Z21.41 (latest edition)
or CAN1-6.9 (latest edition). Provide a restraining device for the gas
line to limit movement of the oven without depending on the connector
and/or any quick-disconnect device or its associated piping to limit
oven movement. Remove two screws from the rear of the oven and
install the tie down strap shipped with the casters using these screws
(Fig. 1). Attach the gas line strain relief to the tie down strap at the
rear of the oven (Fig. 1).
at the rear. Minimum clearance from non-combustible
(15 cm)
at the left side, 4"
(0 cm)
at the right side, and 6"
(10 cm)
– 5 –
at the left side,
(2.5 cm)
at the rear. The
(15 cm)
CONNECT
GAS LINE
STRAIN RELIEF
HERE
Fig. 1
PL-53563