Casio CFX-9850G User Manual page 65

Graphic scientific calculator
Hide thumbs Also See for CFX-9850G:
Table of Contents

Advertisement

Chapter 2: Modes
Setup Mode
This mode lets you set up the data analyzer manually without an external
P.21
program for simple sampling jobs using an Auto-ID probe.
In the Communications Mode, press [SHIFT] [MODE] to enter the Setup Mode,
which is indicated by the READY, SAMPLING, and DONE indicators all flash-
ing on the display. Once in the Setup Mode, you can specify the sample time,
the number of samples, whether or not time data should be recorded, and
whether the time data should be absolute or relative.
The following is the procedure for using the Setup Mode to make manual
settings.
1. In the Communications Mode, press [SHIFT] [MODE] to enter the Setup
• The first setting you can make immediately after your enter the Setup
2. Press [DataLOG] to scroll forward through the available settings and
• Available sample time settings are: 10, 20, 50, 100, 200, 500 (mSec), 1, 2,
3. When the setting you want to use is displayed, press [TRIGGER] to regis-
4. Press [DataLOG] to scroll forward through the available settings and
• Available number of sample settings are: 10, 20 (initial default), 30, 50,
5. When the setting you want to use is displayed, press [TRIGGER] to regis-
6. Press [DataLOG] scroll forward through the available settings and [SHIFT]
• Available time recording settings are: 0: time recording off (initial default),
20
• All settings other than those specifically mentioned above revert to their
defaults and any sample data currently stored in the data analyzer's
memory is cleared whenever you use the Setup Mode to manually change
settings.
• Be sure to connect an Auto-ID probe to the analog channel or SONIC
channel before starting a manual setup procedure.
Mode (indicated by the READY, SAMPLING, and DONE indicators flash-
ing on the display).
Mode is the sample time (indicated by the "mSec" or "Sec" indicator on the
display). The current time setting also appears on the display.
[SHIFT] [DataLOG] to scroll back.
5, 10, 20, 30, 60 (Sec), .000. Selecting .000 indicates manual sampling
that is triggered whenever [TRIGGER] is pressed.
ter it and advance to setting of the number of samples. The current setting
for this item appears on the display.
[SHIFT] [DataLOG] to scroll back.
100, 200.
ter it and advance to time recording settings (indicated by the "RecTIME"
indicator).
[DataLOG] to scroll back.
1: time recording on (absolute), 2: time recording on (relative). Selecting
absolute time causes the "Abs." indicator to appear, while relative time
*2
*1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cfx-9800gEa-100