Automatic operating system shutdown initiated due to fan failure

Event Type: Fan failure
Action: Replace the fan.
Automatic Operating System Shutdown Initiated Due to Overheat
Condition...
...Fatal Exception (Number X, Cause)
Event Type: Overheating condition
Action: Check fans. Also, be sure the server is properly ventilated and the room temperature is set within the
required range.

Blue Screen Trap: Cause [NT]...

...Kernel Panic: Cause [UNIX]
Abnormal Program Termination: Cause [NetWare]
Event Type: System lockup
Action: Refer to the operating system documentation.
Corrected Memory Error Threshold Passed (Slot X, Memory
Module Y)...
...Corrected Memory Error Threshold Passed (System Memory)
Corrected Memory Error Threshold Passed (Memory Module Unknown)
Event Type: Correctable error threshold exceeded
Action: Continue normal operation, and then replace the memory module during the next scheduled
maintenance to ensure reliable operation.

EISA Expansion Bus Master Timeout (Slot X)...

...EISA Expansion Bus Slave Timeout
EISA Expansion Board Error (Slot X)
EISA Expansion Bus Arbitration Error
Event Type: Expansion bus error
Action: Power down the server, and then replace the EISA board.

PCI Bus Error (Slot X, Bus Y, Device Z, Function X)

Event Type: Expansion bus error
Action: Replace the PCI board.